Summary of Contents for Uniden SPU554KTS

  • Page 1 SPU554KTS Trunked/Conventional FM Transceiver W I R E L E S S C O R P O R A T I O N 7100 Technology Drive West Melbourne, FL 32904 Operating Guide RELM WIRELESS CORPORATION ©2000 RELM Wireless Corporation. All Rights Reserved...
  • Page 2: Safety Information

    Warrantor whether or not the Warranty Registration Card is returned, on the condition that other evidence, satisfactory to Uniden, of the date of the Caution: RELM does not represent this radio to be waterproof Do not use the radio in damp original installation or purchase is provided to the Warrantor.
  • Page 3: Table Of Contents

    Technical Support and Service Contents Your Uniden dealer can provide you with technical assistance and information. If your radio does not perform properly, take it to a Safety Information ................2 Uniden dealer for servicing. The radio contains no user-serviceable parts.
  • Page 4 When you talk, the radio switches to the transmit (talk) mode. When you stop talking, it switches back to the receive mode. Optional Accessories & Replacement Parts The following Optional Accessories and Replacement Parts are available from your Uniden Dealer. • Rechargeable Battery Pack (APX1115) •...
  • Page 5: Introduction

    Function Disable Tone - two short low tones indicating that the key function has been turned off. Service If your radio does not work properly, take it to a Uniden dealer for No Function Tone - a low/high/low/high tone sequence indicating the servicing. These radios contain no user serviceable parts. Unauthorized key function is not allowed.
  • Page 6: Features

    The operating frequencies and options have been pre-programmed into selection. Five seconds before the time-out, caution beeps will sound your radio by your Uniden Dealer. Check with your Dealer for the every second. After five seconds, transmission will stop and an error specific features in your radio.
  • Page 7: Unpacking

    • Nickel-Cadmium Rechargeable Battery Pack (APX1115) • Scan - Talk group scan or system scan may be activated from If any of these items are missing from the box, contact your Uniden either key. Dealer for help. • Memo Dial - The memory dial function may be activated to allow recall of stored numbers.
  • Page 8: Controls And Functions

    Controls and Functions Other Functions MENU Operation The MENU key allows accessing menus of up to 7 different functions, if programmed. They are Scan, Memo Dial, TAC, Power, K Tone, K Lock and VOX. Repeatedly pressing the MENU button will sequentially display each of these menu items.
  • Page 9: Getting Started

    the new number for 2 seconds. Additional digits may then be Getting Started entered by pressing the 0-9, * and # keys. Before you can use your radio, you must install and charge the battery 4. When all digits are entered, press the Up-select button to store the and install the antenna as follows.
  • Page 10: Installing The Antenna

    Installing the Antenna DTMF Keypad Functions To install the antenna, align it NOTE: The * and # characters are displayed on the LCD as A and C with the antenna connector on respectively. the top of the radio and turn it clockwise until it seats snugly Manual Dialing - Select an interconnect talk group (indicated by the against the radio.
  • Page 11: General Operation

    TAC ON during the selection process and can be cycled to the General Operation opposite mode by pressing the Up- or Down-select key (if accessed by the MENU key) or the A/B key. When active, TAC mode is LCD Display continuously indicated by the LCD TAC icon.
  • Page 12: Applying Power And Setting The Volume

    Applying Power and Setting the Volume Queueing and Tones l. Turn the radio on by pressing • Busy System Queueing - when programmed for queuring and the POWER button to the in the system is busy when you try to transmit, the radio will position.
  • Page 13: Trunking Mode Operation

    Scan Lock Out Trunking Mode Operation Individual talk groups or complete systems can be locked out of the scan list at any time. Talk Group Selection 1. Up/Down Select- Press the Up/Down key (L or M ) to display the •...
  • Page 14: Transmit

    Transmit Receive Select the talk group you want to receive as indicated above. Scan 1. Select the desired talk group as indicated above. operation may be activated as described below to automatically monitor a number of talk groups. 2. Press the PTT key on the side of the unit. Keep the PTT button depressed while you transmit your message.