Network design tool
Table of Contents

Advertisement

iPOLiS Network Design Tool User Guide
 DVR / Analogue Camera / ETC
D.
Device Capabilities: Display maximum number of connectable devices on SSM.
E.
Advanced Setup – SSM Console Configuration
Configuration Manager>System Manager: Select SSM-System Manager for connecting
to SSM Console, or, delete selected SSM-System Manager.
Connectable SSM-System Manager displays only the list of camera and encoder
which are physically connected to the SSM Console in your diagram.
Only single SSM-System Manager is able to connect to single SSM Console.
Configuration Manager>Media Gateway: Set SSM-Media Gateway for connecting to
SSM-System Manager.
i.
: Resister SSM-Media Gateway to SSM-System Manager
Connectable SSM-Media Gateway displays only the list of camera and encoder
which are physically connected to the SSM-System Manager in your diagram.
Maximum 4EA SSM-Media Gateway are able to connect single SSM-System
Manager.
ii.
: Delete all SSM-Media Gateways are connected in SSM-System Manager.
iii.
: Delete selected SSM-Media Gateways.
iv.
: Resister Network Camera/NVR/Encoder in selected SSM-Media Gateway.
Connectable Network Cameras/Encoders displays only the list of camera and
encoder which are physically connected to the SSM-Media Gateway in your diagram.
Device List : Console에 연결되어 있는 장비의 목록을 확인하고 각 장비의 상세 설정을
변경할 수 있습니다.
Live Channels>Console Live Channels : Console에서 라이브 모니터링을 할 장비를
등록합니다.
Connectable Network Cameras/Encoders displays only the list of camera and
encoder which are physically connected to the SSM Console in your diagram.
You can select specific profile for live monitoring from each Network Camera and
Encoder.
If you don't choose any profile before registration device, system resister profile
no.2 for live monitoring automatically.
A.
Device Information: Basic information of object.
Name: Specify the name of object.
Functions