Download Print this page

DeLonghi HVE 3332 Instruction Manual page 3

Fan heater

Advertisement

5714004300
18-12-2000 14:46
Voltage/ Wattage
ELECTRICAL CONNECTION
-
Before plugging in the heater, check that the voltage of your domestic supply corre-
sponds to the voltage (V) indicated on the appliance.
-
Before using the appliance check that your supply voltage is the same of that shown
on the rating label of the unit.
-
THIS APPLIANCE CONFORMS TO DIRECTIVE 89/336/CEE GOVERNING RADIO
INTERFE-RENCE.
INSTALLATION
The appliance can be used as a portable appliance on a horizontal surface.
IT IS NOT SUITABLE FOR USE IN A BATHROOM .
It can also be wall-mounted, proceed as follows:
Drill the holes in the wall, noting the minimum distances indicated in Fig. 2.
Hang the appliance on the wall using 2 screws and screw fixings and fasten it using
a third screw at the bottom.
The appliance must not be positioned directly underneath a fixed power point.
OPERATION AND USE
Foot switch
This appliance is fitted with an ON/OFF foot switch.
Set the thermostat and your chosen function following the instructions below, and.
simply press the foot switch to start the appliance working.
To switch it off, simply press the foot switch again.
The power plug should be removed from the wall socket when the appliance is not in use.
IMPORTANT
The appliance can only be started when the foot switch is ON
OPERATING THE FUNCTON SELECTOR AND THERMOSTAT (Fig 1)
- Turn the thermostat dial fully clockwise to the maximum position
- Summer use: (ventilation only): turn the dial to position
- Reduced power heating: turn the function selector to position 1.
- Full power heating: turn the function selector to position 2.
- Switching off: turn the function selector to position 0.
SETTING THE THERMOSTAT
When the room has reached the desired temperature, slowly turn the thermostat dial anti-
clockwise, until the appliance switches off and not beyond. The temperature fixed in this way
will be automatically regulated and kept constant by the thermostat.
FROST STAT FUNCTION
Switch on the appliance by pressing the foot switch. It is recommended to select the full
power setting (2 on the function selector), and then turn the thermostat dial in position
The appliance will maintain a minimum room temperature of approximately 5°C to pre-
vent freezing with a minimum energy consumption.
AIRFLOW DIRECTION
THE APPLIANCE CAN BE ADJUSTED AND INCLINED MANUALLY SO AS TO AIM THE FLOW OF
AIR IN THE DESIRED DIRECTION
Pagina 3
See rating label

Advertisement