Generac Power Systems 005308-0 Owner's Manual page 32

17,500 watt portable generator and 60 amp manual transfer switch with built-in load center
Table of Contents

Advertisement

BATTERY CHARGE WINDING
BATTERY CHARGE WINDING
77A
77A
55A
55A
C1-5
C1-5
C1-3
C1-3
10A BATTERY CHARGE WINDING
10A BATTERY CHARGE WINDING
77
77
55
55
C1-10
C1-10
C1-8
C1-8
77
77
77A
77A
ELECTRONIC
ELECTRONIC
VOLTAGE
VOLTAGE
REGULATOR
REGULATOR
86
86
15B
15B
167
167
11S
11S
0
229
229
83
83
TB2 22S
TB2
TB1
TB1
0
229
229
83
83
11S
11S
86
86
15B
15B
167
167
15B
15B
83
83
TR1
TR1
0
167
167
TR2
TR2
86
86
229
229
11S
11S
120V
120V
GFCI
GFCI
RESET
TEST
RESET
TEST
44C
44C
0
22
22
11C
11C
C.B.
C.B.
20A
20A
30
Section 8 — Electrical Data
Commercial-Industrial-Residential Portable Generator System
Schematic, Portable Generator – Drawing No. 0G0733
POWER WINDING
POWER WINDING
66A
66A 11S
11S
11
C1-4
C1-4
C1-1
C1-2
C1-2
66
66
C1-9
C1-9
66A
66A
66
66
11S
11S
I.C.T.
I.C.T.
BLK
BLK
11
11
66
66
77
77
77
77
BCR1
BCR1
BLK
BLK
BLK
11S
11S
22S
22S
4
0
6
162
162
86
86
0
15B
15B
229
229
167
167
83
83
BLK
BLK
BLK
BLK
15
15
229
0
15B
15B
15
15
22S
12
12
10
10 9
4 6
5
22S
22S
18
18
14
14
11S
11S
15B
15B
22S
22S
18
18
1
C2-1
C2-1
CONTROL
CONTROL
2
PRINTED CIRCUIT
PRINTED CIRCUIT
3
BOARD
BOARD
4
5
6
7
8
9
22S
22S
GOVERNOR
GOVERNOR
10
10
ACTUATOR
ACTUATOR
J1
J1
11
11
J2
J2
12
12
120V
120V
DUPLEX
DUPLEX
22
22
120V/30A
120V/30A
TWISTLOK
TWISTLOK
0
22
22
44D
44D
0
C.B.
C.B.
C.B.
C.B.
20A
20A
30A
30A
11
11
22
22
0
44
44
LEGEND
LEGEND
BA - BRUSH ASSEMBLY
BA - BRUSH ASSEMBLY
BCR1 - BATTERY CHARGE RECTIFIER, 10A
BCR1 - BATTERY CHARGE RECTIFIER, 10A
BCR2 - BATTERY CHARGE RECTIFIER
BCR2 - BATTERY CHARGE RECTIFIER
CB1 - 10AMP AUTO RESET BREAKER
CB1 - 10AMP AUTO RESET BREAKER
CB2 - 6AMP AUTO RESET BREAKER
CB2 - 6AMP AUTO RESET BREAKER
D1 - 600V 12A DIODE
D1 - 600V 12A DIODE
D2, D3 - ENGINE SHUTDOWN DIODE
D2, D3 - ENGINE SHUTDOWN DIODE
F1 - 10A FUSE
F1 - 10A FUSE
22S
22S
44
44
22
22
I.C.
I.C.
RED
RED
I.C.T.
I.C.T.
22S
22S
22
22
66A
66A
15
15
77A
77A
BCR2
BCR2
13A
13A
15A
15A
CB1
CB1
22S
22S
4
0
6
162
162
2
CB2
CB2
86
86
0
167
167
83
83
0
SW2
SW2
15
15
15
15
15
15
4
13
13
D1
D1
SSR
SSR
14
14
229
229
R1
R1
14
14
15
15
0
D2
D2
15
15
14
14
167
167
IM1
IM1
SP1
SP1
D3
D3
IM2
IM2
SP2
SP2
22
22
22
22
120/240V
120/240V
120V/30A
120V/30A
30A
30A
TWISTLOK
TWISTLOK
TWISTLOK
TWISTLOK
11D
11D
0
44B
C.B.
C.B.
C.B.
C.B.
30A
30A
30A
30A
11
11
22
22
0
44
44
FSS - FUEL SHUT OFF SOLENOID
FSS - FUEL SHUT OFF SOLENOID
GND - GROUND BAR
GND - GROUND BAR
I.C.T. - IDLE CONTROL TRANSFORMER
I.C.T. - IDLE CONTROL TRANSFORMER
IM1 - IGNITION MODULE, CYL. 1
IM1 - IGNITION MODULE, CYL. 1
IM2 - IGNITION MODULE, CYL. 2
IM2 - IGNITION MODULE, CYL. 2
LOP - LOW OIL PRESSURE
LOP - LOW OIL PRESSURE
R1 - 25 OHM, 25W RESISTOR
R1 - 25 OHM, 25W RESISTOR
SC - STARTER CONTACTOR
SC - STARTER CONTACTOR
DPE WINDING
DPE WINDING
2
6
4
C1-6
C1-6
C1-7
C1-7
C1-11
C1-11
2
6
4
0
12Vdc
12Vdc
0
15
15
4
C2-5
C2-5
LOP
LOP
86
86
86
86
0
C2-12
C2-12
0
0
0
C2-6
C2-6
F1
F1
13
13
13
13
15
15
C2-11
C2-11
SM
SM
13
13
13
13
SCR
SCR
C2-9
C2-9
16
16
16
16
SC
SC
17
17
C2-8
C2-8
17
17
17
17
0
C2-3
C2-3
0
0
SW1
SW1
C2-4
C2-4
167
167
167
167
C2-10
C2-10
15
15
15
15
C2-2
C2-2
15
15
15
15
C2-7
C2-7
14
14
14
14
FSS
FSS
11B
11B
120/240V
120/240V
50A/60A
50A/60A
0
11B
11B
11A
11A
22
22
C.B.
C.B.
C.B.
C.B.
50A/60A
50A/60A
30A
30A
22
22
44
44
SCR - STARTER CONTACTOR RELAY
SCR - STARTER CONTACTOR RELAY
SM - STARTER MOTOR
SM - STARTER MOTOR
SP1 - SPARK PLUG, CYL. 1
SP1 - SPARK PLUG, CYL. 1
SP2 - SPARK PLUG, CYL. 2
SP2 - SPARK PLUG, CYL. 2
SSR - START / STOP RELAY
SSR - START / STOP RELAY
SW1 - START-RUN-STOP RELAY
SW1 - START-RUN-STOP RELAY
SW2 - IDLE CONTROL SWITCH
SW2 - IDLE CONTROL SWITCH
TB1, TB2 - TERMINAL BLOCK
TB1, TB2 - TERMINAL BLOCK
BA
BA
FIELD
FIELD
0
C1-12
C1-12
0
44
44
22
22
0
11
11
0
0
RED
RED
SC
SC
BATTERY
BATTERY
12V
12V
BLACK
BLACK
0
17
17
15
15
0
0
44A 0
44A
11
11
0

Advertisement

Table of Contents
loading

Table of Contents

Save PDF