Important:
Do not use the appliance without filters.

Cleaning the condenser unit

Clean the condenser when light
The condenser is situated at the lower part of the
cabinet behind a small door. To open the door,
push the catch as per picture. During the drying
cycle or at the end, it is normal for water to be
present on the surface of the condenser insertion.
To pull out the condenser, first turn the two red
stops downwards and then remove the
condenser unit holding it at the handle.
Clean it with a brush and rinse it under the
shower if necessary.
Also clean the outside, removing all fluff.
14
09:15
Page 14
Clean the rubber seal round the condenser cab-
inet and in the inner part of the small door with
a damp cloth.
comes on.
Do not use pointed objects or utensils to clean
the spaces between the plates, as this could
damage the condenser and make it permeable.
Re-fit the condenser, turn the red stops upwards
and close the door.
Do not use this appliance if the condenser has
not been fitted.

Emptying the water reservoir

Water extracted from the laundry condenses
inside the machine and is collected in a reservoir.
The reservoir must be emptied after each drying
cycle to ensure efficient operation when the
machine is next used. The pilot light
you this operation.
Proceed as follows:
Important:
Important:
• Open the small door at the lower part of
the cabinet
• Turn the yellow stop upwards
• Pull out the reservoir
• Open the small cover and let water flow
down
• Close the small cover and re-insert cor-
rectly the reservoir