Electrical Adjustments
Group/
Item Name
Item
Group
FAN Option
252
0 HI-LAND SWITCH
1 SAFETY SWITCH
2 FAN MANUAL SWITCH
3 FAN1 MANUAL VOLTAGE
4 FAN2 MANUAL VOLTAGE
5 FAN3 MANUAL VOLTAGE
6 FAN4 MANUAL VOLTAGE
7 FAN5 MANUAL VOLTAGE
8 FAN6 MANUAL VOLTAGE
9 FAN7 MANUAL VOLTAGE
Fan Tem Error Setting (Memorized1
Group
(PT-VX505N/PT-VW435N1
253
0 Temp A Warning (High)
1 Temp B Warning (High)
2 Temp C Warning (High)
3 Temp B-A Warning(High)
4 Temp C-A Warning(High)
5 Temp A Warning (Normal)
6 Temp B Warning (Normal)
7 Temp C Warning (Normal)
8 Temp B-A Warning (Normal)
9 Temp C-A Warning(Normal)
10 Temp A Warning (Eco)
11 Temp B Warning (Eco)
12 Temp C Warning (Eco)
13 Temp B-A Warning (Eco)
14 Temp C-A Warning (Eco)
Temp A Warning Offset
15
(Temp)
Temp B Warning Offset
16
(Temp)
Temp C Warning Offset
17
(Temp)
Temp B-A Warning Offset
18
(Temp)
Temp C-A Warning Offset
19
(Temp)
20 Temp A Warning Offset (Time)
Temp B Warning Offset
21
(Time)
Temp C Warning Offset
22
(Time)
Temp B-A Warning Offset
23
(Time)
Temp C-A Warning Offset
24
(Time)
26 Temp A ForceLamp ECO
Temp A ForceLamp ECO EN-
27
ABLE
Fan Control Range Setting (Temp./Voltage1
Group
(PT-VX505N/PT-VW435N1
254
Normal Fan Control Min
0
Temp
1 Normal Fan Control Max
Temp
2 Normal Fan1 Min
Function
0: Normal, 1: Hi-Land "On1", 2: Hi-
Land "On2"
For test purpose
0: Auto, 1: Manual
Fan Voltage (unit : 0.1V)
Effective only when Fan Manual
switch is 1
Fan Voltage (unit : 0.1V)
Effective only when Fan Manual
switch is 1
Temp. A to judge the Temp Error at
Normal (Room)
Temp. B to judge the Temp Error at
Normal (Panel)
Temp. C to judge the Temp Error at
Normal (Lamp)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
Temp. A to judge the Temp Error at
Eco (Room)
Temp. B to judge the Temp Error at
Eco(Panel)
Temp. C to judge the Temp Error at
Eco(Panel)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
Offset of Temp Error (Temp.)
Error Setting Value is increased XC at
the below condition
* Standby
* Right to turn on the lamp
* Right to change the Lamp mode
Offset of Temp Error (Minutes)
Error Setting Value is increased X min-
ute at the below condition
* Standby
* Right to turn on the lamp
* Right to change the Lamp mode
Initial
-
0
0
100
100
100
100
100
100
100
HiLand-
HiLand-
Normal
Ceiling
Normal Ceiling
ON1/
ON1/
ON2
ON2
9999
9999
9999
9999
9999
45
44
39/35
39/36
64
63
54/50
54/51
65
65
56/58
56/59
28
28
24/22
24/22
21
21
18/16
18/16
49
48
39/36
39/37
68
67
53/50
53/50
65
64
55/57
55/58
34
34
27/25
27/25
26
26
20/17
20/17
5
10
10
100
100
3
3
3
3
3
39
40
37/33
37/34
1
HiLand-
HiLand-
Normal
Ceiling
Normal Ceiling
ON1/
ON1/
ON2
ON2
30
31
26/26
25/26
38
38
34/32
34/33
62
62
82/102 82/102
-57-
Range Note
* Read only
0 - 2
0,3-6
0 - 3
0-255
0-255
0-255
0-255
0-255
0-255
0-255
-
-
-
-
-
30-100
30-100
30-100
0-100
0-100
30-100
-
30-100
0-100
0-100
0-100
0-100
0-100
0-100
0-100
0-5
0-5
0-5
0-5
0-5
20-50
0-1
20-100
20-100
0-255

Hide quick links: