TESTING YOUR CARBON MONOXIDE ALARM
The unit should be tested monthly by pressing and holding the
test button on the front of the unit for 5 seconds. If the unit is
functioning correctly, the green light will stay illuminated, the red
light will flash and the alarm will sound.
SPECIFICATION
Model:
SF450EN
Gas Detected:
Carbon Monoxide
Detection Principle:
Electro-chemical cell
Alarm Indication:
Flashing red light and audible alarm
Alarm Levels:
50ppm Between 60 to 90 mins
100ppm Between 10 to 40 mins
300ppm Less than 3 mins
Operating Temperature:
-10˚C to 40˚C
Humidity Range:
30 to 90% RH
Warm-up time after
initial switch on:
Instantaneous
Normal Operating Life:
Up to 6.5 years
Battery life when in alarm:
At least 5 days
Dimensions:
110mm x 76mm x 34mm
Weight:
Approximately 180g
CARE AND MAINTENANCE OF ALARM
The Carbon Monoxide alarm is pre-calibrated at the factory and
requires no maintenance other than to clean the outside case
occasionally with a clean tissue. Ensure that the holes on the
front of the unit are not blocked with dust or dirt. DO NOT USE
CLEANING AGENTS, BLEACH OR POLISH.
END OF UNIT LIFE
The unit will operate for up to 6.5 years under normal use. The unit
must be replaced when either the end of life signal is given (buzzer
sounds 3 times per minute) or a fault warning signal (1 or 2 chirps
per minute) is given.
DISPOSAL
When the unit has come to the end of its life, dispose of it in
accordance with local regulations.
Normal Operation
When no Carbon Monoxide is present, the green power light will flash
approximately once every minute.
During normal operation the unit carries out a self-check test
every minute.
Alarm Condition
When the unit detects Carbon Monoxide, it will give the alarm signal
continuously. The red alarm light will flash and the buzzer will sound
approximately 5 times per second.
When the unit has been in alarm for 30 minutes the full alarm signal will
be given once every minute.
Alarm Signal
The Carbon Monoxide alarm can be distinguished from smoke detector
alarms as it signals C.O. in morse code (5 per second).
Hush Feature
If required, the audible alarm can be silenced for 5 minutes by pushing
the button marked 'Test'. The red alarm light will continue to flash 5 times
per second.
If Carbon Monoxide is still present after the 5 minute hush period, the
audible alarm will sound.
NOTE: The hush facility will not operate at levels above 350ppm Carbon
Monoxide. At levels below 350ppm the hush facility will only operate
once, ie the audible alarm can only be silenced for one 5 minute period.
Return to Normal Operation
When the Carbon Monoxide gas disperses, the alarm signal will stop. The
green power lamp will continue to flash approximately once every minute.
Fault Warning
If a fault is detected the buzzer will sound 2 short chirps every minute.
The unit must then be replaced.
Battery Fault Warning/End of Battery Life
The buzzer will sound 1 short chirp every minute.
End of Unit Life
When the unit comes to the end of its life the buzzer will sound 3 short
chirps every minute. The unit must then be replaced.
NOTE: With normal use the batteries will last for up to 7 years. However,
battery life will be reduced if either a fault occurs with the battery or the
unit remains in alarm for long periods of time. Should the Battery Fault
Warning occur please contact your supplier.
WHAT TO DO WHEN THE ALARM SOUNDS
If the unit raises an alarm, proceed as follows:
Open all doors and windows to ventilate the area and allow the
Carbon Monoxide to disperse.
Where possible turn off all fuelled appliances and stop
using them.
Evacuate the property leaving the doors and windows open.
Ring the gas or other fuel supplier on their emergency number
and explain the problem. Keep the telephone number in a
prominent place.
Do not re-enter the property until the alarm has stopped.
Get medical help immediately for anyone suffering from the
effects of Carbon Monoxide poisoning such as headaches,
nausea, etc. and advise that Carbon Monoxide poisoning
is suspected.
Do not use the fuel burning appliances again until they
have been checked and cleared for use by a competent
person according to national regulations.
OPERATION OF THE ALARM
Green Power
Red alarm
Light
Light
GAS EMERGENCY SERVICE
TELEPHONE NUMBER
0800 111 999
Contact Numbers for OTHER FUEL Appliances:
OIL USERS:
Contact OFTEC on 0845 658 5080
SOLID FUEL USERS:
Contact HETAS on 0800 600 000
(Please note these numbers are only
available during normal office hours)
Gas appliances should be checked for safety annually by a CORGI
registered installer. Details of local installers can be obtained by
ringing CORGI on 0870 401 2300 or by accessing the website at
www.corgi-gas-safety.com
User Manual also available in Braille. A Carbon Monoxide
safety information sheet is available in: Punjabi; Urdu; Bengali;
Gujarati and Hindi. For copies please call Honeywell Analytics
on: 01202 645577
The Consumer product range from
Honeywell Analytics, the UK's No 1 manufacturer
and supplier of consumer gas alarms.
Buzzer
This Carbon Monoxide alarm is designed to alert you to a
potentially dangerous build-up of Carbon Monoxide gas. It is not
designed to remedy a Carbon Monoxide problem nor to locate a
specific source of Carbon Monoxide. Honeywell Analytics shall not
1 per minute
be liable to pay for any Carbon Monoxide investigation or service
call carried out or arranged in response to an alarm.
5 per 1 second
We guarantee your new Carbon Monoxide alarm for six years
from the date of purchase or until the expiry date on the front of
the unit, whichever occurs first - under normal use and service,
to be free from defects in materials and workmanship.
5 per 1 second
During this period we will, at our discretion, repair or replace
per minute
any part of the Carbon Monoxide alarm which is found to be
defective in either materials or workmanship providing this
occurs under normal use and service. We shall, however, be
(_•_•_ _ _)
under no obligation to repair, or replace units which are found to
c
o
be defective in any way due to damage, neglect, unreasonable
use or which have been tampered with or found to have been
dismantled. Defective units should be returned, in suitable
packaging, along with proof of purchase to
5 per 1 second
CO Returns, Honeywell Analytics, 4 Stinsford Road,
Nuffield Industrial Estate, Poole, BH17 0RZ.
5 per 1 second
An accompanying letter should state clearly any problem
with the Carbon Monoxide alarm. This guarantee does not
affect your statutory rights.
1 per minute
2 per minute
1 per minute
3 per minute
Find out more
www.honeywellanalytics.com
Contact Honeywell Analytics:
Europe, Middle East, Africa and Asia
Honeywell Analytics
4 Stinsford Road
Nuffield Industrial Estate
Poole, Dorset BH17 0RZ
Tel: +44 (0)1202 645577
Fax: +44 (0)1202 665331
consumer@honeywell.com
Americas
Honeywell Analytics Inc.
405 Barclay Blvd.
Lincolnshire, IL 60069
USA
Tel: +1 847 955 8200
Toll free: +1 800 538 0363
Fax: +1 847 955 8208
detectgas@honeywell.com
Technical Services
ha.emea.service@honeywell.com
www.honeywell.com
DISCLAIMER
GUARANTEE
Issue 5 03/07
MAN0849_2109M5500_5
12/07
© 2007 Honeywell Analytics

Hide quick links:

Advertisement

loading