Error
Name
Error 01
Invalid Camera Request
Error 02
Invalid Monitor Request
Error 03
Remote Device Locked by User#
Error 04
Monitor Locked by User#
Error 05
Remote Device Access Restricted
Error 06
Monitor Access Restricted
Error 10
Access Denied
Error 11
Access Denied
Error 15
Invalid User Function
Error 20
Acknowledge Denied
Error 21
Incorrect Acknowledge
Error 22
Acknowledge Disabled
Error 23
Camera not in Alarm
Error 24
Keyboard Not Enabled for
Acknowledge
Error 25
Alarm Switcher Running
Error 50
Sequence Not Available
Error 52
Sequence Request
F.01U.080.637 | 1.92 | 2008.12
Description
The camera number entered from the keyboard does not exist. If
using the optional LTC 8059/00 Master Control Software or the LTC
8850/00 Graphical User Interface Software, ensure that the number
exists in the Camera Identification table. Download the table to be
sure.
The monitor number entered from the keyboard does not exist.
The remote device requested cannot be controlled, because it is
locked by a user with equal or higher priority. Check with the other
users or request that a higher priority user unlock the remote
device.
The monitor requested cannot be accessed, because it is locked by
a user with equal or higher priority. Check with the other users or
request that a higher priority user unlock the monitor.
Remote locked out by Remote Lock Out table.
Monitor locked out by Monitor Lock Out table.
A function was requested for which the user priority is too low. Only
a Priority 2 user or a supervisor with Priority 1 may access this
function.
A function was requested for which the user priority is too low. Only
a supervisor with Priority 1 may access this function.
The function number requested from the keyboard is invalid. Refer
to the User Function table for a listing of valid user function
numbers.
The ACKNOWLEDGE button was pressed by a user without the
authority to acknowledge alarms.
In order to properly acknowledge an alarm event, the keyboard
must be switched to a monitor that is displaying the alarms.
Alarms on this monitor cannot be acknowledged, because that
capability has been disabled by the system programmer.
The camera displayed on the monitor is not an alarm video; only
alarm-generated video can be acknowledged.
This keyboard may not acknowledge alarm video on this monitor; it
has been disabled by the system programmer.
Alarm video may only be acknowledged if the alarm switcher is not
running; press HOLD to stop the switcher.
The user attempted to load a switcher sequence that does not exist.
This is a good way to determine, from the keyboard, which
sequence numbers are unused when desiring to add one. A request
was made to load an ABSOLUTE type sequence, without the
keyboard being on one of the monitors in that sequence. Because
inadvertent loading of monitors should be avoided, the user is
required to switch his keyboard to one of the monitors used by the
sequence. The PROGRAM mode may be used to review which
monitors are used in the sequence.
A request was made to load a RELATIVE type sequence on a monitor
number that is too high; the monitors used by the sequence would
extend past the highest monitor. Try switching to a lower monitor
number before loading the sequence.