Worcester Commercial Boiler Series
GB162 - 65/100
Addendum: Australia / New Zealand
Important Information about this document.
This addendum should be read in conjunction with the attached Installation and Servicing
Instructions. For Australia and New Zealand, information in this addendum takes
precedence over information provided in the Installation and Servicing Instructions. In
particular, AU/NZ contact telephone numbers and AU/NZ standards.
General InformatIon
Please read these instructions carefully before starting installation.
This boiler must be installed by an authorized person only.
Failure to install this boiler correctly could lead to prosecution.
If you are in any doubt contact the Robert Bosch technical
hotline on: 1300 30 70 37 AU or 0800 54 33 52 NZ
Please leave these Instructions, completed Commissioning
Record Log Book and User Manual with the customer after
installing the boiler. The Commissioning Record Log Book is
part of the installation manual.
3 This appliance is only certified for use with Natural Gas in
AU/NZ
3 This appliance can only be connected to the electrical supply
by a qualified electrician
3 Prior to the installation of this appliance, isolate the appliance
and all other BUS connections from the 240V supply.
3 For sealed systems an expansion vessel must be fitted.
3 This appliance is not to be used as a pool heater.
Safety Precautions
If you smell gas:
3 Turn off the eCV (emergency control valve) at the meter
3 Do not turn electrical switches on or off
3 Do not strike matches or smoke
3 Put out naked flames
3 Open doors and windows
3 Keep people away from the affected area
Combustion and corrosive materials
3 Do not store or use combustible materials (paper, thinners,
paints, etc. ) inside or within the vicinity of the boiler
3 Chemically aggressive substances can corrode the boiler and
invalidate any warranty.
Nominal specifications are summarised in the table below:
model
Gas Type
Gas / air ratio pressure (Pa)
Gas valve intel pressure (kPa)
Appliance inlet pressure (kPa)
Injector Size Nominal / (Measured) (mm)
Nominal gas consumption (MJ/h)
Turndown gas consumption (MJ/h)
Note: The pressure valves stated during appliance commissioning were with the appliance door open
GB162 65kW
natural
@Max
-11
@Turndown
-7
@Max
0.85
@Turndown
1.10
1.13
N/A
248
60.6
fittings and modifications
Fitting the boiler and any controls may only be carried out by
an authorized person.
Flue systems must not be modified in any way other than as
described in the fitting instructions. Any misuse or unauthorized
modifications to the boiler, flue or associated components
and systems could invalidate the warranty. The manufacturer
accepts no liability arising from any such actions, excluding
statutory rights.
Servicing
Advise the user to have the system serviced annually by an
authorized person. Approved spares must be used to help
maintain the economy, safety and reliability of the boiler.
Important
The service engineer must complete the service record at the
rear of this manual after each service
Standards
Where no specific instruction is given, reference should be
made to the following standards:
3 AS5601 Gas Installations
3 AS4552 Gas fired water heaters for hot water supply and / or
central heating
3 AS/NZS 3000 electrical Installations
3 AS 1697 Installation and maintenance of steel pipe systems
for gas
3 AS4032 Water supply - valves for the control of hot water
supply temperatures
3 AS3498 Authorisation requirements for plumbing
3 AS1910 Water supply - float control valves for use in hot and
cold water, AS 3500 National plumbing and drainage code.
GB162 100kW
natural
-14
-3
0.83
1.08
1.13
ø8.4/ 8.39
(Verified by Vemier Calliper)
386
78.4

Advertisement

loading

Summary of Contents for Worcester GB162 - 65/100

  • Page 1 Failure to install this boiler correctly could lead to prosecution. described in the fitting instructions. Any misuse or unauthorized If you are in any doubt contact the Robert Bosch technical modifications to the boiler, flue or associated components hotline on: 1300 30 70 37 AU or 0800 54 33 52 NZ and systems could invalidate the warranty.
  • Page 2 Horizontal and vertical flue terminal positioning Flue terminal positions for boilers in accordance with AS5601 H, I 3 Pluming will occur at the terminal so terminal Key to illustration positions where this could cause a nuisance should Balanced flue terminal position be avoided.