INSTALLATION
SETTING ThE TURN-ON

mOdE SwITCh

The SI-1230 has three turn-on modes. Select
the mode you want by sliding the mode switch.
See Installation Considerations on page 14 for
more information about each of the turn-on
modes.
TIP: To conserve energy set the TURN ON mode to
either AUDIO SENSE or TRIGGER INPUT. Use of the
CONSTANT mode will prevent the amplifier from
turning off when not in use wasting energy.
ThE CONTROL OUTpUT
This terminal provides a 12V DC signal
suitable for triggering Niles automated
switchers, some motorized screens, some
electric curtain controls, etc. This voltage
is present only when the amplifier is active
or on. When the amplifier turns off, the 12V
signal is off.
STEp
1. check the requirements of the device you
want to control.
2. connect the 3.5 mm Jack to the control
output maintaining proper polarity
(tip = +).
24
TURN ON MODE
AUDIO SENSE
CONSTANT
SliDe The SwiTch wiTh eiTher
your FinGernail or 1/8"
SloTTeD ScrewDriVer blaDe
DESCrIpTIon
The control output has a maximum
current capability of 150 ma.
niles makes an accessory cable plug
FG00724.
WWW.NILESAUDIO.COM
3-30V
AC/DC
TRIGGER
INPUT