Transmitter section
Item
Condition
1. Frequency
1) CH: TX center
2) Transmit
2. High power
1) CH: TX low
CH: TX low'
CH: TX center
CH: TX high'
CH: TX high
2) Transmit
3. Low Power
1) CH: TX low
CH: TX low'
CH: TX center
CH: TX high'
CH: TX high
2) Transmit
4. DQT
1) CH: TX low:
CH: TX center:
balance
CH: TX high:
2) Transmit
5. Max
1) CH: TX low:
deviation
CH: TX center:
CH: TX high:
2) AG: 1kHz/50mV
3) Transmit
6. Mic
1) CH: TX center:
sensitivity
2) AG: 1kHz/5mV
3) Transmit
7. QT
1) CH: TX low:
deviation
CH: TX center:
CH: TX high:
2) Transmit
8. QT
1) CH: TX low:
deviation
CH: TX center:
CH: TX high:
2) Transmit
9. DTMF
1) CH: TX center:
2) Transmit
deviation
Test frequency(MHz)
Channel
TX
RX
1: Center
160.100
160.050
2: Low
146.100
146.050
3: High
173.900
173.950
4
160.000
160.000
5
160.200
160.200
6
160.400
160.400
TK-260
:K, K2
ADJUSTMENT
Measurement
Test equipment
Frequency
counter
Power meter
Wide
Modulation
analyzer or linear
Wide/Narrow
Wide
detector(LPF: 3kHz)
Oscilloscope
Wide
Modulation
analyzer or linear
Wide/Narrow
Wide
detector(LPF: 15kHz)
Oscilloscope
AG
AF.V.M
Wide/Narrow
Wide
Modulation
Wide/Narrow
analyzer or linear
Wide
detector(LPF: 3kHz)
Oscilloscope
Wide
Wide/Narrow
Wide
Wide/Narrow
Adjustment
Terminal
Parts
Method
ANT
PC key
Adjust to center frequency
25W
5W
Adjust the waveform as below
4.0kHz: Wide
ANT
MIC
2.0kHz: Narrow
According to the large +,-
Check
0.75kHz: Wide
0.35kHz: Narrow
0.75kHz: Wide
0.35kHz: Narrow
3.0kHz: Wide
1.5kHz: Narrow
TK-7102
Specifications/
Remarks
within 100Hz
1.0W
0.5W
50Hz
3kHz 0.2kHz: Wide
1.5kHz 0.1kHz: Narrow
0.05kHz
0.05kHz
0.2kHz