Honeywell RTH111 Quick Installation Manual page 13

Non-programmable thermostat
Hide thumbs Also See for RTH111:
Table of Contents

Advertisement

Available languages

Available languages

System Setup (cont'd)
Function
Temperature display
1
format
Heating cycles per
2
hour
Compressor
3
protection
*
Damage can occur if the compressor is restarted too soon after
shutdown. This feature forces the compressor to wait 5 minutes before
restarting. During the wait time, the message Cool On or Heat On
flashes on the screen. When the safe wait time has elapsed, the
message stops flashing and the compressor turns on.
Non-programmable Thermostat RTH111
*
Default
setting
0: Fahrenheit
0
1: Celsius
2 to 6 cycles per hour
• 2: 30 min (steam, gravity)
• 3: 20 min (hot water, 90%+
5
high-efficiency furnace)
• 4: 15 min (gas or oil)
• 5: 12 min (gas or oil)
• 6: 10 min (electric)
0: Off
1
1: On
11
Options
10.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rth2300

Table of Contents