Disassociating A Fabric Extender From An Interface; Configuring The Fabric Extender - HP Integrity Superdome 2 16-socket Getting Started Manual

Fabric extender
Hide thumbs Also See for Integrity Superdome 2 16-socket:
Table of Contents

Advertisement

Configuring the Cisco Nexus B22 Fabric Extender for HP

Disassociating a Fabric Extender from an Interface

To disassociate the Fabric Extender from an interface, perform this task:
Command
switch(config-if)# no fex associate

Configuring the Fabric Extender

To configure global features for a Fabric Extender, perform this tasks:
Command
Step 1
switch# configure terminal
Step 2
switch(config)# fex chassis
Step 3
switch(config-fex)# description desc
switch(config-fex)# no description
switch(config-fex)# pinning max-links
uplinks
switch(config-fex)# no pinning max-links
switch(config-fex)# serial serial
switch(config-fex)# no serial
switch(config-fex)# beacon
switch(config-fex)# no beacon
Cisco Nexus B22 Fabric Extender for HP Getting Started Guide
10
Eth100/1/5
Eth100/1/6
Eth100/1/9
Eth100/1/10
Eth100/1/13
Eth100/1/14
Eth100/1/7
Eth100/1/8
Eth100/1/11
Eth100/1/12
Eth100/1/15
Eth100/1/16
Purpose
Disassociates the Fabric Extender unit attached to the
interface.
Purpose
Enters configuration mode.
Enters configuration mode for the specified Fabric
Extender chassis ID. The range of the chassis ID is
from 100 to 199.
Specifies the description. The default is the string
FEXxxxx where xxxx is the chassis ID. If the chassis
ID is 123, the description is FEX0123.
Deletes the description.
Defines the number of uplinks. The default is 1. The
range is from 1 to 4.
This command is only applicable if the Fabric
Extender is connected to its parent switch using one
or more statically pinned fabric interfaces. There can
only be one EtherChannel connection.
Resets the number of uplinks to the default.
Defines a serial number string. If this command is
configured, then a switch will only allow the
corresponding chassis ID to associate (using the fex
associate command) if the Fabric Extender reports a
matching serial number string.
Configuring a serial number other than that of the
given Fabric Extender will force the Fabric Extender
offline.
Deletes the serial number string.
Turns on the beacon LED. This LED allows you to
locate a specific Fabric Extender in a rack.
Turns off the beacon LED.

Advertisement