NOTE:
The HPIMA_POLLFREQ is only available on HP Integrity systems running Linux.
You can validate any changed agent polling intervals by using the snmpget command as
described in
"Viewing a Polling Interval" (page
NOTE:
The snmpget/snmpset commands fail if the corresponding hardware is not present
on the system. For example, if the system has no SCSI devices the hpimascsid process can not
run so attempting to get or set the cpqScsiOsCommonPollFreq.0 agent fails.
TIP:
If you want to manually trigger a single polling loop for all agents, without effecting the
actual OID polling interval settings, to refresh data when the server is in a known quiescent state,
you can use the following command:
# /etc/init.d/hpima sample [agent]
The use of the agent string is optional and when used only the agent specified is polled rather
than all agents.
At this time, you must use SNMP commands to change the polling interval values as this facility
is not available within the HP System Management Homepage.