10A-400V DC Power distribution units and plugs
Specification of Power Distribution Units
Product name
5 outlets
Part number
10 outlets
No of outlets
Configulation
Socket
-outlet
Rated
per outlet
power
per unit
Input
Rated power
Insulation resistance
Insulation
Dielectric
strength
Inrush current
Insertion/withdrawal life
Rated power
Electrical life
(Switch)
Inrush (300A)
5 outlets
Dimensions
(W x D x H)
10 outlets
Specification of Plug with Cable
Product name
Main specification for Plugs with cable
Cable length (approx.)
Saf-D-Grid plug
Terminal
Part
treatment
Round crimp connector
number
No connector
Rated voltage/current
Insulation resistance
Insulation
Dielectric strength
Insertion/withdrawal life
Cable
* Saf-D-Grid plug is the product of Anderson Power Products, Inc.
Always carefully read and understand the product manual and/or delivery specifications for proper operation and handling before actual use.
Use only at the specified rated supply voltage.
Never install the products in a wet, highly humid, dusty, oily or smoky environment.
The products in this document are designed for general use. They are not for use in equipment that poses high fatal risks or danger and not for
use requiring extremely high reliability such equipment in nuclear facilities, medical life support system, etc.
GLOBAL MARKETING DEPT. 2 MARKETING DIV.
3-5, Higashi-gotanda 2-chome, Shinagawa-ku, Tokyo, 141-0022 Japan
TEL (81-3)5449-7014 FAX (81-3)5449-2626
URL http://www.fcl.fujitsu.com/en/
E-mail promothq@fcl.fujitsu.com
Specifications are subject to change without notice.
For the latest information, contact your local representative.
You may have to comply with related state regulations or related export
rules.
Company names and product names mentioned in this leaflet are
trademarks or registered trademarks of their respective owners.
Outlet bar
Outlet box
FDU-A105
FDU-X105
FDU-A110
FDU-X110
5 outlets / 10 outlets
First make last break
10A-400VDC 4kW
25A-400VDC 10kW
400VDC +7.5% -30%、10kW (at resistive load)
Min 5MΩ (1kVDC、b/w DC power lines - ground pin)
2500VDC for 1min.
(b/w DC power lines - ground pin, b/w DC lines)
Max. 300A
5000 cycles
5000 operations
500 operations
380 x 44.4 x 67 mm
482 x 44.4 x 134 mm
600 x 44.4 x 67 mm
482 x 88.5 x 160 mm
Plug with cable
1.5m
(*)
FDU-P115/AP
FDU-P115/CT
FDU-P115
260VDC to 420VDC / 10A
Min. 5MΩ(at 500VDC, b/w adjacent contacts)
2500VDCfor 1min. (b/w adjacent contacts)
5000 cycles
PSE 2.0sq cable
Safety Precautions
2.0m
3.0m
FDU-P120/AP
FDU-P130/AP
FDU-P120/CT
FDU-P130/CT
FDU-P120
FDU-P130
Outer dimensions (5 outlets type)
Outlet bar
Top view
380
Side view
Outlet box
Top view
440
465
482
Side view
Note) The dimensions are for reference.
Types of plug with cable
Saf-D-Grid plug
Round crimp connector
No connector
Copyright 2012 FUJITSU COMPONENT LIMITED
(unit:mm)
June. 12, 2012

Advertisement

loading

This manual is also suitable for:

Fdu-a105Fdu-a110Fdu-x105Fdu-x110