Lennox Shadowdance LSVFSD-18 Installation And Operation Instructions Manual

Shadowdance series vent-free millivolt dual-listed gas log sets
Hide thumbs Also See for Shadowdance LSVFSD-18:

Advertisement

Consumer: Retain This Manual For Future Reference.
I
n the Commonwealth of Massachusetts:
• Installation must be performed by a licensed plumber or gas fitter
• See Table of Contents for location of additional
Commonwealth of Massachusetts requirements
• Hot! Do not touch! This appliance will be hot during operation and will retain heat for a while after
shutting off the appliance. Severe burns may result.
• Carefully supervise children in the same room as appliance.
• Improper installation, adjustment, alteration, service or maintenance can cause injury or property
damage. Refer to this manual. For assistance or additional information consult a qualified installer,
service agency or the gas supplier.
• Do not build a wood fire. Do not burn wood or other material in these appliances.
• Carefully review the instructions supplied with the decorative type unvented room heater for the minimum fire-
place size requirement. Do not install the appliance in the fireplace, unless the fireplace meets the minimum
dimensions required for the installations (see Page 3).
• This is an unvented gas log appliance. It uses air (oxygen) from the room in which it is installed. Provisions for adequate
combustion and ventilation air must be provided. Refer to Combustion and Ventilation Air Section on Page 5.
• Important: Read and understand these instructions completely before installing your unvented room heaters.
• This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible
for use with other gases. If the gas supply differs, DO NOT INSTALL the appliance. Contact your dealer to obtain
the correct appliance.
• This appliance may be installed in an aftermarket, permanently located, manufactured (mobile) home, where
not prohibited by local codes.
• Lennox
vent-free gas logs are designed for use as a supplemental heater. They are not intended for continuous use
®
as a primary heat source.
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property
damage, personal injury or loss of life.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
• Do not light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow your gas supplier's instructions.
• If your gas supplier cannot be reached, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier
INSTALLATION AND OPERATION INSTRUCTIONS
Vent-Free Millivolt
Dual-Listed Gas Log Sets
Gas Train Models:
LSVFSD-NG
LSVFSD-LP
Log Sets Sold Separately
P/N 850051M Rev. C, 03/2011
Installer: Leave This Manual With The Appliance.
Log Set Models:
LSVFSD-18 Logs
LSVFSD-24 Logs
LSVFSD-30 Logs
US
Report No.116-L-49-5
WARNINGS
Portland
Shadowdance™ Series
TM
.

Advertisement

Table of Contents
loading

Summary of Contents for Lennox Shadowdance LSVFSD-18

  • Page 1 INSTALLATION AND OPERATION INSTRUCTIONS Vent-Free Millivolt Dual-Listed Gas Log Sets Gas Train Models: Log Set Models: LSVFSD-NG LSVFSD-18 Logs LSVFSD-LP LSVFSD-24 Logs LSVFSD-30 Logs Log Sets Sold Separately P/N 850051M Rev. C, 03/2011 Installer: Leave This Manual With The Appliance.
  • Page 2: Important Safety Information

    IMPORTANT SAFETY AND WARNING WARNINGS INFORMATION • Allow the appliance to cool before servicing. Always shut off any electricity or gas to the appliance while READ THIS MANUAL IN ITS ENTIRETY AND UNDER- performing service work. STAND THESE RULES TO FOLLOW FOR SAFETY. •...
  • Page 3: Table Of Contents

    (see Page 15 for ordering information) thank you for selecting a lennox Hearth Products gas log heaters INTRODUCTION as the answer to your home heating needs. these gas log appliances incorporate unitized ceramic fiber logs which provides some glow realistically when the appliance is operating.
  • Page 4: Tools Required

    SEE TABLE 3 ON PAGE 16 FOR BTU INPUT AND GAS PRESSURE CODES REQUIREMENTS adhere to all local codes or in their absence the latest edition of the Do not install these Dual-Listed Gas Log Appliances in a bedroom or National Fuel gas code aNsi Z223.1 or NFPa 54-latest edition which can a bathroom as all units exceed maximum allowable BTU/hr input of be obtained from the american National standards institute, inc.
  • Page 5: New Your City (Mea) Approval

    NEW YORK COMBUSTION AND VENTILATION AIR installation of these gas log heaters are approved in the state of New York this heater shall not be installed in a confined space or unusually tight and are prohibited in New York city. construction unless provisions are provided for adequate combustion and ventilation air.
  • Page 6: Preinstallation

    4. compare the maximum Btu/Hr the space can support with the actual Note: Illustrations shown in this manual reflect “typical” installations amount of Btu/Hr used. with nominal dimensions and are for reference only. Actual installations may vary due to individual design preferences. However, always main- _________ Btu/Hr tain minimum clearances to combustible materials and do not violate (max.
  • Page 7 Noncombustible Material Requirements with No Mantel Installed (A) Noncombustible Requirements for Safe Installation Material Measurement 12" or more adjustable canopy not required. 42" 8" minimum to 12" install adjustable canopy. Min. less than 8" extend noncombustible material to at least 8" and install adjustable canopy (Figure 4).
  • Page 8: Installation

    Example: The bottom of the mantel may project from the wall a maxi- INSTALLATION mum of 2-1/2" at a minimum of 8" above the opening. The top shelf of the mantel may project a maximum of 6" at a minimum of 14-1/2" above the opening.
  • Page 9: Gas Pressure Check

    replace the test point plug after pressure measurement ensuring no the appliance gas inlet connection is 3/8" NPt at the regulator/valve, located on the left side facing the appliance. if a right side connection is gas leaks. required, the connection pipe may be piped under the rear of the appliance to end at the left hand side for connection to the inlet.
  • Page 10: Log Placement Instructions

    4. Place left and right front logs onto front grate locating pins as LOG PLACEMENT INSTRUCTIONS shown in Figure 14. 1. Place rear ember bed as shown in Figure 11. Top Burner Install Right Front Log Left Front Log Ember bed from behind Locating top burner...
  • Page 11 7. Place the right top log onto rear log locating pin and the right 9. Place the front ember bed log as shown in Figures 18A and front log locating pin as shown in Figure 17. 18B. Right Top Log 18"...
  • Page 12: Pilot Flame Appearance

    Burner And Flame Characteristics WARNING the shadowdance™ gas log set features a new concept in integrated Failure to position the parts in accordance with Figure burner and log design. the flames from the burner travel horizontally 21 or failure to use only parts specifically approved through the log set and emerge at the knot holes.
  • Page 13: Operation And Care

    only limited cleaning will be required under the normal use of the appli- OPERATION AND CARE OF YOUR APPLIANCE ance. Dust the front grate, the top of the piezo cover and the control knob occasionally. Do not use cleaning fluids to clean the logs or any other 1.
  • Page 14: Accessories

    Deluxe Remote Control System ACCESSORY COMPONENTS (Model RC-STAT) the model rcl-t (Deluxe) remote control system All options are available in kit form, are easy to install and are pack- has all of the features of the standard system aged complete with all required parts and instructions. Some of the along with an added easy to read lcD screen option kits need to be fitted prior to completing the installation of the which presents access to many enhancements,...
  • Page 15 Bag of Volcanic Stone Gas Log Sets* Volcanic stone is available for use with these appliances. Cat. No. Model No. Description H5137 LSVFSD-18 Logs Shadowdance™ 18" Logs Decorative Volcanic Stone H5138 LSVFSD-24 Logs Shadowdance 24" Logs Cat. No. Model No.
  • Page 16: Millivolt Wiring Diagram

    CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. PILOT (O.D.S.) If any of the original wire as supplied must be replaced, it must be replaced ASSEMBLY with Type AWM 105°C – 18 GA. wire. MILLIVOLT VALVE WHITE WHITE...
  • Page 17: Operating Instructions - Millivolt

    LIGHTING INSTRUCTIONS – MILLIVOLT FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. this appliance has a pilot which must be lighted with a piezo •...
  • Page 18: Troubleshooting Guide

    VENTED/UNVENTED TROUBLESHOOTING GUIDE OBSERVED PROBLEM POSSIBLE CAUSE REMEDY 1. When igniter button is A. igniter electrode positioned wrong. replace igniter. pressed, there is no spark B. igniter electrode broken. replace igniter. at oDs/pilot. C. igniter electrode not connected to igniter cable. reconnect igniter cable.
  • Page 19: Replacement Parts List - Millivolt

    REPLACEMENT PARTS LIST (MILLIVOLT) - SHADOWDANCE™ SERIES Replacement Parts List (Millivolt) - Shadowdance™ Series, Models LSVFSD-NG and LSVFSD-LP (18" and 24") Description Catalog Number Valve, millivolt (Natural) H1203 Valve, millivolt (Propane, l.P.g.) H4278 ember Bed Front H3910 ember Bed rear H3911 Bottom Burner H3912...
  • Page 20 Fuel type (check one) c Natural gas c Propane gas (lP) lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. consult your local distributor for fireplace code information.

Table of Contents