Introduction
These instructions should be carefully read to ensure safe and economical
use of your boiler.
The Keston Celsius 25 is a high efficiency central heating condensing boiler
designed to provide central heating and indirect sanitary hot water supply.
They are designed for use with fully pumped systems only. This boiler is
supplied for natural gas use only.
Servicing
To ensure continual safe and efficient operation of the boiler it is
recommended that the appliance be checked and serviced as necessary at
regular intervals. Generally once per year will be sufficient. It is the law that
any servicing must be carried out by a competent person.
NB:
There are no user servicable parts inside the boiler cabinet. The
cabinet should only be removed by a qualified competent person.
Clearances
If fixtures are to positioned close to the boiler the following minimum
clearances must be observed: Top : 100 mm, Bottom : 100 mm, Left : 1 mm,
Right : 1 mm & Front : 305 mm. Extended clearance is required to the front to
allow for access for servicing.
Cleaning
Normal casing cleaning only requires dusting with a dry cloth. To remove
more stubborn marks wipe with a damp cloth and finish with a dry cloth.

Users Instructions

Advertisement

loading

Summary of Contents for Keston Celsius 25

  • Page 1: Users Instructions

    These instructions should be carefully read to ensure safe and economical use of your boiler. The Keston Celsius 25 is a high efficiency central heating condensing boiler designed to provide central heating and indirect sanitary hot water supply. They are designed for use with fully pumped systems only. This boiler is supplied for natural gas use only.
  • Page 2: Boiler Setup

    Frost Protection The Celsius 25 has an integral frost protection thermostat. However, care should also be taken to ensure that any exposed pipework is adequately insulated to prevent freezing.
  • Page 3 WD211/0/2000 USER FAULT DISPLAY TABLE MAINS BOILER LOCKOUT OTHER FAULT DESCRIPTION (GREEN) (RED) LAMPS ACTION TO TAKE (YELLOW) No power to boiler. Check power supply. Rapid Flash Boiler off on front. Turn User Control Knob to On. Slow Flash External controls not calling for heat. Flashing DIAG LED Flow Overheat.
  • Page 4 WD211/0/2000 BENCHMARK INITIATIVE As part of the industry wide “Benchmark” Initiative all Celsius 25 boilers now include a Benchmark Installation, Commissioning and Service Record Log Book. This log book should be completed by your installer at the end of the installation and commissioning process. The details of the Log Book will be required in the event of and warranty work being required.