D. REMOVING MAGNETRON
(Figures 11 Through 13)
(1) Remove vertgrille.
(2) Remove mount all.
(3) Remove outcase.
(4) Discinnect the wireleads.
(5) Remove the 3 screws and Magnetron very
carefully.
vertgrille
mount all
Figure 11
NOTES:
• When removing the magnetron, make sure that its
dome does not hit any adjacent parts, or it may be
damaged.
• When replacing the magnetron, be sure to install the
magnetron gasket in the correct position and be sure
that the gasket is in good condition.
• After replacing the magnetron, check for microwave
energy leakage with a survey meter Check
microwave energy leakage must be below the limit of
5 mW/cm
. (All service adjustments should be made
2
for minimum microwave energy leakage readings.)
Magnetron
Figure 13
7-8
outcase
Figure 12