QuickSpecs

Technical Specifications

System Unit
Dimensions
(H x W x D)
(with feet/bezel)
Weight
(approximate)
Input Requirements
(per power supply)
BTU Rating
Power Supply Output
(per power supply)
System Inlet
Temperature
Relative Humidity
(non-condensing)
Altitude
DA - 14340 North America — Version 24 — December 13, 2013
HP ProLiant ML350e Generation 8 (Gen8)
18.19 x 8.58 x 29.13 in (46.2 x 21.8 x 74.0 cm)
Maximum
(all hard drives, power
supplies, and processors
installed)
Minimum
(one hard drive, power
supply, and processor
installed)
Rated Line Voltage
Rated Input Current
Rated Input Frequency
Rated Input Power
Maximum
Rated Steady-State Power 460(750) W (at 100 VAC)
Maximum Peak Power
Operating
Non-operating
Operating
Non-operating
Operating
96.67 lb (43.85 kg)
57.21lb (25.95 kg)
100 to 240 VAC
7.1 Amps (at 120VAC) to 3.5 Amps (at 240 VAC)
50 to 60 Hz
852 W
460W - 1773 BTU / hr (at 120 VAC), 1715 (at 240
VAC)
750W - 2892 BTU / hr (at 120 VAC), 2797 (at 240
VAC)
1200W - 3530 BTU / hr (at 120 VAC), 4600 (at 240
VAC)
460(750) W (at 200 VAC)
460(750) W (at 100 VAC)
460(750) W (at 200 VAC)
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 304.8 m (1.8°F
per every 1000 ft) above sea level to a maximum
of 3048 m (10,000 ft), no direct sustained
sunlight. Maximum rate of change is 10°C/hr
(18°F/hr). The upper limit may be limited by the
type and number of options installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.
5 to 95% relative humidity (Rh), 38.7°C (101.7°F)
maximum wet bulb temperature, non-
condensing.
3048 m (10,000 ft). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).