Download Print this page
Ryobi 2000i Inverter Operator's Manual

Ryobi 2000i Inverter Operator's Manual

Inverter parallel kit

Advertisement

Quick Links

OPERATOR'S MANUAL
INVERTER PARALLEL KIT AUN9230PK
For use only with the following Inverter
Generators:
Ryobi RYi2200 Series
PowerStroke PSi2000 Series
Ariens ARi2000 Series
Gravely GVi2000 Series
WARNING!
READ AND UNDERSTAND ALL INSTRUCTIONS.
Failure to follow all instructions listed below may result
in electric shock, fire and/or serious injury.
WARNING!
To reduce the risk of injury, user must read and
understand the operator's manual for their generator
and this instruction sheet. Ensure compatibility and fit
before using any accessory. Do not use an accessory if
a part is damaged or missing. If you are not comfortable
performing any of the functions described in these
instructions, take your unit to an authorized service
center.
 This product is for outdoor use only.
 Do not attach parallel kit while inverter generator are
running.
 Do not get the product wet. Do not use if this product
is exposed to moisture.
 Do not disassemble. This product has no user-
serviceable parts.
 As with all electrical devices, use caution when
plugging and unplugging this unit into an outlet or
plugging/unplugging other devices into this unit. Do
not force this unit into an outlet. Do not force plugs into
this unit.
 If required, use only UL/ETL approved extension cords
with this product.
 If this product is used in a manner not specified by
the manufacturer, the protection provided by this
equipment may be impaired.
 Do not overload the parallel kit. The kit can supply a
maximum of 30 amps at 120 V or 3600 watts depending
on the rating of the inverter generators.
 Do not parallel more than two inverter generators.
 Save these instructions. Refer to them frequently and
use them to instruct others who may use this product.
If you loan someone this product, loan them these
instructions also.
990000108
8-24-12 (REV:01)
SPECIFICATIONS
Maximum Running Watt Rating............................... 3600 W
Maximum Starting Watt Rating ...............................4500 W
Output ..............................................................120 V / 30 A
APPLICATIONS
You may use this product for the following purpose:
 Link two inverter generators together for the sum of the
two inverter wattage rating.
CONNECTING THE PARALLEL KIT
See Figures 1 - 3.
The AUN9230PK parallel kit can be used to link any of the
following series of inverter generators: RYi2200, PSi2000,
ARi2000, or GVi2000.
NOTE: Must use two of the same model inverter generators
together. Do not link different brands and models.
 Turn off inverter generators according to the instructions
included with your models.
NOTE: Do not connect or disconnect the parallel kit while
the inverter generators are running.
 Position inverter generators and parallel kit as shown in
figure 2.
NOTE: Parallel kit may also be hung nearby, using
hanging brackets. see figure 4.
 Remove any load from the inverter generators.
 Connect the parallel kit cables to the parallel kit terminals
on the inverter generators.
 Loosen screws on ground terminals on inverters. Attach a
ground wire to each inverter. Tighten securely.
 Turn on the inverter generators according to the instructions
included with your model.
 Connect devices to power/charge into appropriate
receptacles.
 When finished, turn off the inverter generators and
disconnect the parallel kit.
HANGING THE PARALLEL KIT
See Figure 4.
 Screws or nails for hanging the parallel kit should be
spaced 4-1/4 in. from center to center.
 Mark the 4-1/4 in. measurement on a wall stud or other
sturdy wood surface.
 Drill holes and insert the screws; tighten the screws se-
curely into the wood. If using nails, the nail head should
be large enough to hold the parallel kit.
NOTE: There should be at least 5/8 in. of the screws or
nails protruding from the wood piece for hanging the
parallet kit.
 Hang the parallel kit on the screws or nails, making certain
it is secure.
CALIFORNIA PROPOSITION 65
WARNING:
This product may contain chemicals, including lead,
known to the State of California to cause cancer, birth
defects or other reproductive harm. Wash hands after
handling.
ILLUSTRATIONS
Fig. 1
B
A
C
D
E
A - 120 volt AC 30 amp receptacle (TT-30R) RV (prise de 120 v c.a. 30 a
[TT-30R] RV, receptáculo de 120 v c.a. 30 a [TT-30R] RV)
B - 120 volt AC 30 amp (L5-30R) twist (120 v c.a. 30 a (L5-30R) rotation,
120 v c.a. 30 a (L5-30R) fijación)
C - Parallel kit cables (câbles de l'ensemble parallèle, cables del equipo
para funcionamiento)
D - Ground wire (câble de mise à la terre, cable de conexión a tierra)
E - Hanging bracket (dispositif d'ancrage, soporte de suspensión
Fig. 2
Ryobi RYi2200 Series
D
B
C
E
A
A - Inverter parallel kit (ensemble en parallèle pour à inverseur, juego para
conexión en paralelo de inversor)
B - Ground terminal (borne de terre, ground terminal)
C - Ground wire (-) (câble de mise à la terre,cable de conexión a tierra)
D - Parallel kit terminals (terminaux de l'ensemble parallèle, paralelo a los
terminales)
E - Parallel kit cables (câbles de l'ensemble parallèle, cables del equipo
para funcionamiento)
Fig. 3
PowerStroke PSi2000 Series
Ariens ARi2000 Series
C
Gravely GVi2000 Series
D
B
D
E
A
A - Inverter parallel kit (ensemble en parallèle pour à inverseur, juego para
conexión en paralelo de inversor)
B - Ground terminal (borne de terre, ground terminal)
C - Ground wire (-) (câble de mise à la terre,cable de conexión a tierra)
D - Parallel kit terminals (parallel kit terminals, parallel kit terminals)
E - Parallel kit cables (parallel kit cables, parallel kit cables)
Fig. 4
1/4"
E
4-1/2"
OWT INDUSTRIES, INC.
Highway 8, Pickens, SC 29671
1-866-340-3912
C
E

Advertisement

loading

Summary of Contents for Ryobi 2000i Inverter

  • Page 1 Fig. 3 For use only with the following Inverter PowerStroke PSi2000 Series Output ..............120 V / 30 A Generators: Ariens ARi2000 Series APPLICATIONS Ryobi RYi2200 Series Gravely GVi2000 Series You may use this product for the following purpose: PowerStroke PSi2000 Series  Link two inverter generators together for the sum of the...
  • Page 2 PowerStroke PSi2000 Series PowerStroke serie PSi2000 usarse para conectar generadores inversores de las siguientes régime nominal des deux onduleurs. Ariens ARi2000 Series series: RYi2200, PSi2000, ARi2000 o GVi2000. Ariens serie ARi2000 BRANCHEMENT DE L’ENSEMBLE PARALLÈLE NOTA: deben usarse dos generadores inversores del mismo modelo.

This manual is also suitable for:

Aun9230pk