Adjustment
THE SAFETY REVERSE SYSTEM TEST IS IMPORTANT. GARAGE DOOR MUST REVERSE ON CONTACT WITH A
ONE INCH OBSTACLE PLACED ON THE FLOOR. FAILURE TO PROPERLY ADJUST OPENER MAY RESULT IN
SERIOUS PERSONAL INJURY FROM A CLOSING GARAGE DOOR. REPEAT TEST AT LEAST FOUR TIMES A YEAR
AND ADJUST AS NEEDED..
PROCEDURE: Place a 1-inch obstacle on the floor under the
garage door. Operate door in DOWN direction. The door must
reverse on the obstruction.
If a the door STOPS on the obstruction, it is not traveling far
enough in the DOWN direction. Increase the DOWN limit by
turning DOWN limit adjustment screw counterclockwise 1/4 turn.
REPEAT TEST.
NOTE: Make sure limit adjustments do not force the door
arm beyond a straight up and down position. See the
illustration on Page 13.
When the door reverses on the 1-inch obstacle, remove the
obstruction and run the opener through a complete travel cycle.
Door MUST NOT reverse in closed position. If it does, repeat
Adjustment Steps 1, 2 and 3.
REPEAT ADJUSTMENT STEP 3 AFTER:
• EACH ADJUSTMENT OF DOOR ARM LENGTH, CLOSE FORCE OR DOWN LIMIT.
• ANY REPAIR OR ADJUSTMENT OF GARAGE DOOR (INCLUDING SPRINGS AND HARDWARE).
• ANY REPAIR OR BUCKLING OF THE GARAGE FLOOR.
• ANY REPAIR OR ADJUSTMENT OF THE GARAGE DOOR OPENER.
(Optional)
The PROTECTOR SYSTEM
measure of safety against a small child being caught under a
garage door. It uses an invisible beam which, when broken by an
obstruction, causes a closing door to open and prevents an open
door from closing.
After the garage door opener has been completely installed and
adjusted, the PROTECTOR SYSTEM
installed. Instructions are included with this optional device.
STEP 3

Test Safety Reverse System

STEP 4
provides an ADDITIONAL
accessory can be

Install the Protector System

18