Installation
[] ELECTRICAL
CONNECTION
iNFORMATiON
WARNING-
TO REDUCE
THE RISK OF
FIRE, ELECTRICAL
S HOCK, AND
PERSONAL
INJURY:
* DO
NOT
USE
AN EXTENSION
CORD
CRAM
ADAPTER
PLUG
WITH
THIS
APPLIANCE.
D1yer
must
be electrically
grounded
in accordance
with
local
codes
and
ordinances,
or in tile
absence
of local
codes,
in accordance
with
tile NATIONAL
ELECTRI-
CAL
CODE, ANSI/NFPA
NO. 70.
ELECTRICAL REQUIREMENTS
Tiffs appliance
must
be supplied
with 120V, 60Hz,
and
com_ected
to a properly
grounded
branch
circuit,
protected
by a 15- or 20-
amp
circuit
breaker
or time-delay
fi_se. If electrical
supply
provid-
ed does not meet
the abo_e
specifications,
it is recommended
that
a licensed
electrician
install
an approved
outlet.
_WARNING
- THIS
DRYER
IS EQUIPPED
A THREE-PRONG
(GROUNDING)
PLUG
FOR
YOUR
PROTECTION
AGAINST
SHOCK
HAZARD
AND SHOULD
BE PLUGGED
DIRECTLY
INTO
A PROPERLY
GROUNDED
THREE-PRONG
RECEPTACLE.
DO NOT
CUT
OR REMOVE
THE GROUNDING
PRONG
FROM
THIS
PLUG.
ENSURE
PROPER GROUND
EXISTS
BEFORE USE.
IFLOCAL C ODES PERMIT,
AN EXTERNAL GROUND W IRE
(NOT PROVIDED),
WHICH MEETS
LOCAL C ODES, MAYBE ADDED
BY ATTACHING TOTHE GREEN
GROUND S CREW ONTHEREAR
OFTHEDRYER, ANDTOA GROUNDED
METAL C OLD WATER PIPE OROTHER
ESTABLISHED
GROUND.
instructions
4
F6-] E XHAUST
iNFORMATiON
_WARNING-
IN CANADA AND IN THE UNITED
STATES, THE REQUIRED
EXHAUST DUCT DIAMETER
IS 4 IN (102ram).
DO NOT USE DUCT LONGER
THAN SPECIFIED IN THE EXHAUST LENGTH TABLE.
l_ sing exhaust
longer
than
specified
length
wilh
* Increase
the chying
times
and the energ F cost.
* Reduce
the cho_er life.
* Accumulate
lint, creating
a potential
fire hazard.
The correct
exhaust
installation
is YOUR
RESPONSIBILITY,
Problems
due to incorrect
installation
are not covered
by the warranty.
Remove
and discard
existing
plastic
or metal
foil transition
duct
and replace
with I_L listed
transition
duct.
The MAXIMI_
M ALLOWABLE
duct
length
and number
of
bends
of the
exhaust
system
depends
upon
the type of duct,
number
of turns,
the type of exhaust
hood
(wall cap),
and all
conditions
noted
below.
The
maximum
duct
length
for rigid
metal
duct is shown
in the table
below.
EXHAUST
LENGTH
RECOMMENDED
MAXIMUM LENGTH
Exhaust
Hood Types
Recommended
Use only for short
run installations
4" DIA.
4"
_
_
2-1/2"
No. of 90 -0
Rigid
Rigid
Elbows
Metal
Metal
0
90 Feet
60 Feet
1
60 Feet
45 Feet
2
45 Feet
35 Feet
3
35 Feet
25 Feet
EXHAUST
SYSTEM
CHECK LiST
HOOD
OR WALL (AP
• Terminate
in a manner
to prevent
back drafts or entry of birds or
other wildlife.
• Termination
should present
minimal
resistance
to the exhaust
air flow
and should require
little or no maintenance
to prevent
clogging.
• Never install a screen in or over the exhaust duct.This could canse lint build up.
• Wall caps must be installed at least 12 in. above ground
level or any other
obstruction
with the opening
pointed
down.
SEPARATION
OF TURNS
For best perfermance,
separate
all turns by at least 4 ft. of straight duct,
including
distance
between
last ttlrn and exhaust
hood.
TURNS
OTHER
THAN 90 °
* Oile ttlrn of 45 ° or less may be ignored.
, Two 45 ° tt/rns shouht be treated
as one 90 ° tt/rn.
, Each tt/rn over 45 ° shouhl be treated
as one 90 ° tt/rn.
SEALING
OF JOINTS
* _Mljoints should be tight te avoid leaks. The male end of each section
of
duct must point away flom the dryer.
* Do not assemble
the ductwork
with fasteners
that extend
into the duct.
They will serve as a collection
point fer lint.
Duct joints can be made air and moisture-tight
by wrapping
the
overlapped
joints
with d t_ct rope.
Horizontal
runs should slope down toward the outdoors
_½ inch per feot
iNSULATION
Duct work that runs through
an unheated
area or is near air conditioning
shouhl be insulated
to reduce
condensation
and lint buihl-t_p.