1.3 SPECIFICATIONS

ITEMS
CAPACITY(Pints/24hrs)
POWER SUPPLY(Phase,V,Hz)
INPUT(W)
RUNNING CURRENT(A)
ENERGY FACTOR(L/kw.h)
REFRIGERANT
REFRIGERANT CHARGE, oz(g)
THERMISTOR
SOLENOID VALVE
COMPRESSOR MODEL No.
P.T.C ASSEMBLY
PROTECTOR
CAPACITOR
MOTOR ASSEMBLY,SINGLE
SWITCH ASSEMBLY,MICRO
OUTSIDED MENSIONS WxHxD,mm(in)
NET WEIGHT,kg(lbs)
*NOTE: Specifications are subject to minor change without notice for further improvement.
MODELS
OPEN
CLOSE
TYPE
TIME
MAXIMUM AMPERE
VOLTAGE
BHD-301
30
480
5.9
1.23
R134a
5.29(150)
LX86HAQG
P6R8MC
"WORKING
TIME:0.3~1.3sec
RETURN TIME:65sec"
10A
200V
OVERLOAD PROTECTOR FOR COMPRESSOR
INTERNAL PROTECTOR(FUSE)FOR MOTOR
-
Shaded pole motor,72W/1.4A,Thermal cutoff:266°FV/130°C
385X540X340(15 5/32 x 21 1/4 x 13 3/8)
23.1(51)
—4—
BHD-501
50
1Ø, 115V,60Hz
630
5.7
1.56
R22
7.23(205)
33.8˚F(1±0.5°C)
50˚F(10±0.5°C)
Using Temp/Humid.:-4~122˚F(-20~50°C)/95%RH
Rating:7W/90mA
QA084CBC
-
35µF,270VAC
Shaded pol e motor,91W/1.8A,Thermal cutoff:266°FV/130°C
15A/250VAC
20.4(45)
BHD-651
65
830
8.4
1.54
8.82(250)
QA114CBD
35µF,270VAC
22.2(49)