PERFORMANCE DATA
NO LOAD & NO DOOR OPENINGS AT MID-POINT
CONTROL SETTING
Type A with Run/Start Capacitor
65ºF (18ºC) Ambient
Operating Time
32 to 40%
Freezer Temperature
0º to 4ºF (-18º to -16ºC)
-1º to 3ºF (-18º to -16ºC)
Refrigerator Temperature
34º to 39ºF (1º to 4ºC)
Low Side Pressure (cut-in)
5 to 12 psig (34 to 83 kPa)
5 to 12 psig (34 to 83 kPa)
Low Side Pressure (cut-out)
-2 to 2 psig (-14 to 14 kPa)
-2 to 2 psig (-14 to 14 kPa)
High Side Pressure
90 to 115 psig
(Last 1/3 of cycle)
(621 to 793 kPa)
Wattage (Last 1/3 of cycle)
120 to 150
Amps (Running)
1.2 to 1.5
Base Voltage
115 vac (127 vac max)
Refrigerant Change
4.25 oz. (121 g)
DEFROST SPECIFICATIONS
Thermostat
Cabinet Size
Cut-In
Cut-Out
23' & 26'
25ºF (-4ºC)
47ºF (8ºC)
Electronic Timer - (ADC) Defrost 24 minutes every 6 to 72 hours of compressor run time.
CONDENSER FAN MOTOR
Watts
RPM
3.1 (Energy Star - Some models)
1100 CW Opposite Shaft
8.0
2550 CW Opposite Shaft
ICE MAKER SPECIFICATIONS
Electrical
115 vac (127 vac max)
Thermostat
Opens at 48ºF (9ºC)
Heater Wattage
165
ICE MAKER PLUG CONNECTIONS
Wire Number
Wire Color
1
Green/Yellow
2
Yellow
3
Black
4
Lt. Blue
ICE MAKER INFORMATION
Test Cycling: Remove cover by inserting screw-
driver in notch at bottom and prying cover from
housing. Use screwdriver to rotate motor gear
counterclockwise until holding switch circuit is
completed. All components of ice maker should
function to complete the cycle.
Water Fill Volume: The water fill adjustment
screw will change the fill time. One full turn is
equal to 20cc (.68 oz.). The correct fill is 102 to
130cc (3.4 to 4.3 oz.). When a water valve is
replaced, the fill volume must be checked.
90ºF (32ºC) Ambient
55 to 65%
IMPORTANT SAFETY NOTE
The information provided herein is designed to assist qualified repair personnel only. Untrained persons
34º to 39ºF (1º to 4ºC)
should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord
before servicing this appliance.
IMPORTANT
If any green grounding wires are removed during servicing, they must be returned to their original
130 to 155 psig
position and properly secured.
(896 to 1069 kPa)
130 to 160
CAUTION
1.2 to 1.5
All electrical parts and wiring must be shielded from torch flame. DO NOT allow torch to
touch insulation; it will char at 200°F and flash ignite (burn) at 500°F. Excessive heat will
115 vac (127 vac max)
distort the plastic liner.
SPECIAL MODES
Display
Heater
FZ
Watts
Ohms
Manual
450
30
Defrost
d
Amps
Showroom
77
.03 Running
.07 Running
Service
No
Display
60 Hertz
Closes at 15ºF (-9ºC)
°F
kOHMS
Connect to:
-10
11.75
Ground
-9
11.41
Water Valve
-8
11.01
-7
10.69
Line
-6
10.32
Neutral
-5
10.02
-4
96.79
-3
93.47
-2
90.80
-1
87.71
0
85.22
1
82.34
2
80.02
3
77.34
4
75.18
5
72.68
6
70.27
7
68.33
8
66.08
9
64.27
10
62.17
SERVICE DATA SHEET
242293200
ICE & WATER - AUTOMATIC DEFROST
SIDE BY SIDE MODELS - R134a
ERROR CODES
Display
FF
FZ
FF
Press and hold FRZ UP then
Flashing
press FRZ DOWN key 5 times
F
OP
---
Open FZ Thermistor
within 6 sec. Same
to deactivate.
---
OP
Open FF Thermistor
Press and hold FF UP then press
SH
---
Shorted FZ Thermistor
FF DOWN 3 times within 5 sec.
---
SH
Shorted FF Thermistor
77
Displays will flash "0" "0". Press
FRZ UP within 5 sec. Requires
Solid
Power-on-Reset to deactivate.
HI
---
FZ Temp. above 26ºF
Press and hold FRZ UP then
---
HI
FF Temp. above 55ºF
press FRZ DOWN 3 times within 6
sec. Press and hold FRZ UP key
for 5 sec. to deactivate. Automati-
cally deactivates after 5 minutes
of inactivity.
TEMPERATURE/RESISTANCE CHART
FOR FRESH FOOD AND FREEZER THERMISTORS
°F
kOHMS
°F
kOHMS
11
60.48
32
32.51
12
58.52
33
31.53
13
56.94
34
30.74
14
55.11
35
29.82
15
53.34
36
29.07
16
51.91
37
28.21
17
50.25
38
27.51
18
48.92
39
26.70
19
47.37
40
26.04
20
46.12
41
25.28
21
44.67
42
24.54
22
43.50
43
23.94
23
42.14
44
23.25
24
40.83
45
22.67
25
39.77
46
22.03
26
38.55
47
21.50
27
37.56
48
20.89
28
36.41
49
20.39
29
35.48
50
19.81
30
34.40
51
19.25
31
33.53
52
18.80
Press and hold FRZ UP then press FRZ DOWN 3 times within 6 sec. Input is recognized
Activate:
once FRZ UP is released. Press FRZ UP or DOWN to change test.
Press and hold FRZ UP for 5 seconds. Diagnostic mode will automatically deactivate after 5
Deactivate:
minutes of inactivity.
• Press FRZ UP or DOWN to change test.
• Press FF UP or DOWN to change between sub tests.
• View UI display for results of tests.
• Listen for operating sounds; feel for heat or air flow as appropriate to determine results of tests.
Test
Test Name
Sub Test Test Description
---
Display is blank when selecting test.
A
Displays last 4 digits of software variant; record sequence.
1
Software
B
Displays last 4 digits of control and housing assembly part number; record sequence.
C
Displays software test number.
---
Display is blank when selecting test.
Evaporator
2
A
Turns on evaporator fan, displays "E".
Fan
B
Turns off evaporator fan, displays "_".
---
Display is blank when selecting test.
FZ
A
Flashes "1" if good, "SH" if shorted, and "OP" if open.
3
Thermistor
Displays current FZ temperature. If technician puts hand around thermistor, the
B
temperature will rise.
---
Display is blank when selecting test.
FF
A
Flashes "1" if good, "SH" if shorted, and "OP" if open.
4
Thermistor
Displays current FF temperature. If technician puts hand around thermistor, the
B
temperature will rise.
Note: Evaporator fan will be on for the duration of this test to aide in evaluation of the damper.
---
Display is blank when selecting test.
A
Damper opens, displays "0". If there is a switch or motor error, flashes "4".
B
Damper closes, displays "_". If there is a switch or motor error, flashes "4".
Damper
5
Motor
If A or B did not display a "4" this test will display "_" and the motor will not run.
If "4" was displayed in test A or B this test displays "E", and runs the motor
continuously. If motor movement is not heard, there is a problem with the
C
motor or motor circuit.
If motor is running, there is a problem with the damper switch or damper
switch circuit.
---
Display is blank when selecting test.
6
Defrost
A
Turns on defrost heater, displays "d" if DTT is closed and "_" if DTT is open.
B
Turns off defrost heater, displays "_".
---
Display is blank when selecting test.
Compressor
A
Turns on compressor and condenser fan, displays "C".
and
7
Condenser
Turns off compressor and condenser fan, displays "_" .
°F
kOHMS
Fan
B
Once compressor is turned off it cannot be turned on for 7 minutes. 7 minute
53
18.27
countdown is displayed in test A.
54
17.84
---
Display is blank when selecting test.
8
Display
55
17.34
A
Turns on all segements of FF display, FZ display, and all LEDs.
56
16.93
---
Display is blank when selecting test.
57
16.39
Error
Displays maximum of 8 errors from the last 10 days. If there are no errors,
9
A
History Log
displays "-" on single digit and "- -" on dual digit.
58
16.08
B
Flashes bottom and middle segments. Press and hold FF DOWN to erase history.
59
15.64
60
15.21
Error
61
14.86
62
14.46
3
63
14.13
4
64
13.74
5
65
13.43
6
66
13.07
15
67
12.78
23
68
12.44
24
69
12.10
25
70
11.84
26
71
11.52
27
72
11.27
33
73
10.97
SERVICE MODE
TEST 9 ERROR CODES
Error History Log Codes
Open FZ Thermistor
Shorted FZ Thermistor
Damper did not move from close to open position in allotted time
Damper did not move from open to close position in allotted time
DTT Connector Out or Shorted DTT
User Interface Key Stuck Down
Open FF Thermistor
Shorted FF Thermistor
FZ High Temperature Alarm
FF High Temperature Alarm
Heater, Heater Circuit, Heater Wiring, or DTT Problem

Advertisement

loading

Summary of Contents for Frigidaire 242293200

  • Page 1 NO LOAD & NO DOOR OPENINGS AT MID-POINT Press and hold FRZ UP then press FRZ DOWN 3 times within 6 sec. Input is recognized 242293200 Activate: once FRZ UP is released. Press FRZ UP or DOWN to change test.
  • Page 2 242300700 Wiring Diagram PTC STARTER WITH RUN CAPACITOR START ICE & WATER CONTROL BOARD ELECTRO-MECHANICAL DISPENSER OVERLOAD COMP. MOTOR STARTER WATER DISP . RED/BLK (120 VAC) SWITCH (LINE) (NEUTRAL) ICE DISP. SWITCH NEUTRAL COMM COMM CAPACITOR IS ONLY USED WITH LINE DISPENSER HOUSING HEATER SOME P.T.C.