Download Print this page
Panasonic CS-S12NKUA Information
Panasonic CS-S12NKUA Information

Panasonic CS-S12NKUA Information

Split system wall mounted air conditioner's low ambient models
Hide thumbs Also See for CS-S12NKUA:

Advertisement

Quick Links

Split System Submittal Data
Indoor: CS-S12NKUA
Outdoor: CU-S12NKUA
Wall Mounted Air Conditioner's
Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
Power
Circuit Ampacity
Fuse Size, Max.
Compressor
No. used
Output Power
Outdoor Unit
Fan type
Motor Type
Output Power
Airflow
Coil Type
Fin Type - Pipe Type
Rows - F.P.I
Face Area
Indoor Unit
Fan type
No. Speeds
RPM
Motor Output
CFM
(QLo/Lo/Me/Hi/SHi)
Indoor Sound Rating
Coil Type
Fin Type - Pipe Type
Rows - F.P.I
Face Area
Drain Connection Size
Operating Range
Cooling
Indoor Air Intake Temp.
Maximum
90F DB/74F WB
Minimum
60F DB/52F WB
Low Ambient Models
V/PH/Hz
(A)
(A)
DC Rotary Inverter
(W)
DC Motor ( 8 poles )
(W)
CFM
Aluminum ( Blue Coated )
Corrugated Fin
(sq.ft)
(High)
(W)
191/230/311/395/434
(Hi) (dB-A)
Aluminum Fin & Copper Tube
Slit Plate - Inner Rifled
(sq.ft)
(in.)
Outdoor Air Intake Temp.
Approval:
Date:
Construction:
Unit #:
Drawing #:
230/208/1/60
Refrigerant
15
Lbs. - R410a (outdoor unit)
15
Control
Connection
Line Length, Max (ft.)
1
Lift Difference, Max (ft.)
700
Line Size
Line Size
Propeller
Dimensions
Indoor Unit
40
1095
Outdoor Unit
2 - 17
Weight
2.8
Net
Shipping
Performance Data @ ARI Standard Conditions (230/208V)
Cross Flow
Cooling
5
Total Capacity
1300
SEER
40
Dehumidification
Amps
40
Power Inputs
Outdoor Sound Rating
2-19
Features
2
Wireless Remote Controller Standard
5/8"
Wired Remote Controller ( CZ-RD516C ) Optional
Controls
Remote ControllerLCD Wireless Type, Temp, Sensor Built In
Temperature Control
115F DB
Air Louver
0F DB
Power Failure Automatic Restart
Self-Diagnosis
Air Filter
49 (outdoor lower), 49 (outdoor higher)
(in. O.D. Discharge)
(in. O.D. Suction)
(in.)
Height
(Uncrated)
11-7/16"
(Crated)
(Uncrated)
21-9/32"
(Crated)
(lbs.)
(lbs.)
(BTU/H)
(Pints/H)
(A)
(W)
(dB-A)
Microprocessor
IC Thermostat
(Horizontal)
(Vertical)
Washable, Anti-Mold
R410A
2.13
Electric Expansion Valve
Flare
100
1/4"
1/2"
Width
Depth
34-9/32"
8-1/16"
30-23/32"
11-13/32"
Indoor
Outdoor
20
82
13300
20
2.5
4.7
650
47
Manual
Automatic
Built-In
Built-In

Advertisement

loading

Summary of Contents for Panasonic CS-S12NKUA

  • Page 1 Split System Submittal Data Indoor: CS-S12NKUA Outdoor: CU-S12NKUA Wall Mounted Air Conditioner's Low Ambient Models Job Name: Approval: Location: Date: Engineer: Construction: Submitted to: Unit #: Submitted by: Drawing #: Reference: Power V/PH/Hz 230/208/1/60 Refrigerant R410A Circuit Ampacity Lbs. - R410a (outdoor unit) 2.13...
  • Page 2 Indoor Dimensions Outdoor Dimensions...

This manual is also suitable for:

Cu-s12nkuaCs-s12nkuw-1Cu-s12nku-1