Quick Links

Split System Submittal Data
Wall Mounted Heat Pump
System: KE36NKU Indoor/Outdoor: CS-KE36NKU/CU-KE36NKU
Job Name:
Location:
Engineer:
Submitted to:
Submitted by:
Reference:
Power
V/PH/Hz
Circuit Ampacity
Fuse Size, Max.
Compressor
No. used
R.L. Amps - L.R.
Outdoor Unit
Fan type
Dia. (in.) - No. Speeds
Type Drive
No. Poles
No. Motors
(High)
CFM
F.L. Amps
Coil Type
Fin Type - Pipe Type
Rows - F.P.I.
(sq.ft.)
Face Area
Tube Size
Indoor Unit
Fan type
Dia. & Length (in.) - No. Speeds
No. Speeds
No. Poles
(RPM, High)
No. Motors
(HI/Med/Lo)
CFM
Indoor Sound Rating
(Hi) (dB-A)
F.L. Amps
Coil Type
Aluminum Plate Fin & Copper Tube
Fin Type - Pipe Type
Rows - F.P.I.
Face Area
(sq.ft.)
Tube Size
Drain Connection Size
General Data (at 230V)
230/208/1/60
(A)
16.5-18.0
(A)
DC Rotary Inverter
(A)
20.0-31.0
Propeller
19-9/32-1
DC Motor
(RPM)
(W)
(A)
19.6/21.5
Aluminum Fin & Copper Pipe
Slit Plate - Inner Rifl ed
(in.)
Cross Flow
3 - 15/16 L32
8 - 1370
(W)
630/530/412
(A)
Slit Plate - Inner Rifl ed
(in.)
(in.)
Approval:
Date:
Construction:
Unit #:
Drawing #:
45
Refrigerant
Lbs. - R410a (outdoor unit)
Control
1
Connection
Line Length, Max (ft.)
Lift Diff erence, Max (ft.)
Line Size
Line Size
Dimensions
Indoor Unit
8 - 750
1 - 142
2060
Outdoor Unit
Weight
Net
2-21.2
Shipping
8.05
3/8"
Shipping Volume
Performance Data @ ARI Standard Conditions (230/208V)
Cooling
3
Total Capacity
Sensible Capacity
47
Latent Capacity
SEER
Dehumidifi cation
49
0.4
Amps
Power Inputs
Outdoor Sound Rating
2 - 19.5
Heating
Total Capacity
4.55
HSPF
3/8"
1-1/4"
Electric Expansion Valve
50 (outdoor lower), 100 (outdoor higher)
(in. O.D. Discharge)
(in. O.D. Suction)
(in.)
(Uncrated)
11-3/16 x 41-15/16 x 9-1/16
(Crated)
12-7/32 x 44-7/8 x 14-31/32
(Uncrated)
35-13/16 x 37-1/32 x 13-3/8
(Crated)
42-3/8 x 40 x 16-3/8
Indoor
(lbs.)
32.0
(lbs.)
39.7
Indoor
(cu.ft.)
4.59
(BTU/H)
34,000 (10,900-34,000)
(BTU/H)
(BTU/H)
(Pints/H)
(A)
(W)
(dB-A)
(BTU/H) 36,000 (14,000-36,000)
R410A
6.5
Flare
165
3/8"
5/8"
H x W x D
Outdoor
185.2
207.2
Outdoor
15.88
20,700
13,300
16
10.64
20-21.9
4,000
55
9.0

Advertisement

loading

Summary of Contents for Panasonic KE36NKU

  • Page 1 Split System Submittal Data Wall Mounted Heat Pump System: KE36NKU Indoor/Outdoor: CS-KE36NKU/CU-KE36NKU Job Name: Approval: Location: Date: Engineer: Construction: Submitted to: Unit #: Submitted by: Drawing #: Reference: General Data (at 230V) Power V/PH/Hz 230/208/1/60 Circuit Ampacity 16.5-18.0 Fuse Size, Max.
  • Page 2 Dimensions Heating Options Available Amps Refrigerant Line Set 18.2/19.9 Max. Amps Fresh Air Intake 18.2/19.9 Power Inputs 3,650/3,650 Airduct Extension Outdoor Sounds Rating (dB-A) Indoor Frame Extension Condensate Drain Pump Available Non-Removeable Remo-con Bracket Available Features Controls Microprocessor Operating Range Remote Controller LCD Wireless Type, Temp.