TYPICAL 24VAC 4 WIRE HOOKUP
SINGLE STAGE HEATING AND COOLING
G O Y2 Y1 RC C RH W1 W2 E B
JUMPER
PROVIDED
SYSTEM COMMON
COMPRESSOR
FAN
TYPICAL 5 WIRE HOOKUP
SINGLE STAGE HEATING AND COOLING
G O Y2 Y1 RC C RH W1 W2 E B
COOL
COMMON
COOLING
FAN
COMPRESSOR
XFMR 1
AC LINE
GAS
XFMR
VALVE
AC LINE
HEATING
GAS
XFMR 2
VALVE
AC LINE
6
TYPICAL INSTALLER SETUP:
[0 1 ]
SYSTEM TYPE = FURNACE
[0 2 ]
HEAT STAGES =1
[0 3 ]
COMPRESSOR STAGES = 1
[04]
MODES = Ht-Off-Cl-Auto
[ 09 ]
HEAT FAN CONTROL
= GAS
NOTES:
[ 1 ]
OPTIONAL COMMON
ALLOWS USE OF
SYSTEM POWER
TYPICAL INSTALLER SETUP:
[0 1 ]
SYSTEM TYPE = FURNACE
[0 2 ]
HEAT STAGES =1
[0 3 ]
COMPRESSOR STAGES = 1
[04]
MODES = Ht-Off-Cl-Auto
[ 09 ]
HEAT FAN CONTROL
= GAS
NOTES:
[ 1 ]
OPTIONAL COMMON
ALLOWS USE OF
SYSTEM POWER