Location
Emplacement d'instaliation
NOTE:There must be at least one wall stud within cabinet opening.
NOTE: II faut qu'il y ait au moins un poteau du colombage mural dans I'espace d'installation entre les placards.
30"min, cabinet
opening width
largeur- 30 pc min.
(placard)
f
A
to floor
jusqu'au
plancller
I
I
I
wall studs
poteaux de
celumbage
12 _ 14 pa
I
i
!
.........
II
I .............
q
I --
.............
J
I
-
I
Product Dimensions
Dimensions du produit
T
16-1/4"
L
/
66" min. from floor to top of wall mounting
plate.
66 pc min. entre le plancher et le sommet de
la plaque de montage.
30" min. to cooking surface (or countertop)
below microwave hood.
30 pc min. jusqu'au plan de travail (ou _ la
table de cuisson) sous I'ensemble Four
micro-ondes/Hotte.
Checkthe opening where the microwave hood will be
installed. The location must provide:
V" 2" x 4" wood studding and 3/8" thickness drywall or
plaster/lath.
V" Support for weight of 150 pounds, which includes
microwave hood combination and items placed in the
oven and upper cabinet.
7 30" wide minimum opening.
€" 12"to 14" recommended upper cabinet depth to
allow for removal or servicing if needed.
€" Protection from draft areas, such as windows, doors
and strong heating vents.
V" Grounded electrical outlet. See "Electrical
Requirements".
Inspecter I'emplacement d'installation de I'ensemble Four
micro-ondes/Hotte. [_'emplacementdolt comporter :
7 Poteaux de colombage mural de 2 pc x 4 pc, et parement de
pl_tre ou cloisons @ches de 3/8 pc.
7 Capacit_de support pour 150 livres -ceci inclut I'ensemble
Four & micro-ondes/Hotte etles articles plac6s dans le four
et dans le placard.
7 Largeur de 30 pc ou plus.
€" Placard muraux - profondeur de placard recommand@ 12
14 pc, ce qui permettra la d@ose etles op6rations de
service si n6cessaire.
7 Protection centre les courants d'air (fen6tre, porte, bouche
de chauffage/ventilation).
7 Prise de courant @ctrique reli@ & la terre. Voir
"Sp@ifications de I'alimentation 61ectrique'.
4
Electrical
Electrical
Shock Hazard
Plug into a grounded
3-prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result
in death, fire, or electrical shock.
3-prong
ground plug
fiche de
branchement _ 3
@
broches ( liaison
,aterrel
cord
groundprong
cordon
brochn deliaison
d'alimentation _ la tnrre
_leotrique
3-prong ground-type
wall receptacle
prise decourant
_lectrique_ 3 alv_oles
(liaison_ la terre)
Alimentation
61ectrique
Risque de choc _lectrique
Brancher
sur une prise a 3 alv_oles
reli_e a la terra.
He pas enlever la broche de liaison a la terre.
Ne pas utiliser un adaptateur.
He pas utiliser
un c_ble de rallonge.
Le non-respect de ces instructions peut causer un
d_c_s, un incendie, ou un choc _lectrique.
Important: Observeall governing codes and ordinances.
It is the customer's responsibility:
To contact a qualified electrical installer.
To assure that the electrical installation is adequateand in
conformance with National Electrical Code, ANSI/NFPA70
-- latest edition*, and all local codes and ordinances.
You must have:
/
120-volt, 60Hz, AC-only, 15- or 20-amp., fused
electrical supply.
7
outlet located in the upper cabinet as close as
possible to the microwave hood.
We recommend:
7
a time-delay fuse or circuit breaker.
7
a separate circuit serving this appliance only.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.
Recommendedground method
For your personal safety, this appliance must be grounded. This appliance is equipped with
a power supply cord having a 3-prong ground plug. To minimize possible shock hazard,the
cord must be plugged into a mating 3-prong ground-type wall outlet, grounded in
accordance with the National Electrical Code, ANSI/NFPA70 -- latest edition*, and all local
codes and ordinances.
Copies of the standards listed may be obtained from:
* National Fire Protection Association
Batterymarch Park
Qoincy, Massachasetts 02269
Important : Respecter les dispositions de tous les codes et
r6glements en vigueur.
C'est & I'utilisateur du produit qu'incombe la
responsabilit6 :
De contacter un @ctricien qualifi6.
De veiller & ceque I'installation @ctrique soit ad@uate et
conforme aux prescriptions de la plus r6cente _dition* du code
National Electrical Code, ANSI/NFPA70 -- et de tousles codes
et r_glements Iocaux en vigueur.
Source d'_lectricit_ n_cessaire:
V" circuit 120 volts, 60 Hz, CA seulement, 15 ou 20 A, avec
protection par fusible.
7 prise de courant 61ectriqueinstall@ dans le placard mural,
aussi pr6s que possible de I'ensemble Four & micro-
ondes/Hotte.
Nous recommandons:
V" protection du circuit par fusible temporis6 ou disjoncteur.
7 alimentation de I'appareil par un circuit ind@endant.
Siun conducteur distinct est utilis6 pour la liaison & la terre
Iorsque le code le permet, un @ctricien qualifi6 devrait v6rifier la
qualit_ de la liaison & la terre.
IVi thode recommand ede liaison
la terra
Pour la s@urit_des utilisateurs,il faut que cet appareilsoit @ctriquement reli__ la
terre. L'appareil c omporteun cordon d'alimentation@ctrique dot_d'une fiche de
branchement&3 broches. Pour minimiserle risquede choc @ctrique, on dolt
brancherla fichesur une prisede courant 61ectrique de m6me configuration,reli@&la
terre conform_mentaux prescriptionsde la plus r@ente_dition* du code National
Electrical C ode,ANSI/NFPA 70 -- et de tous lescodes et r_glementsIocauxen vigueur.
Pour obtenir un exemplaire des hermes mentionnSes, contacter :
* National Fire Protection Association
Batterymarch Park
5
Quincy, MassachaseNs 02268