Major Component Specifications; (A) Indoor Unit - Sanyo SPW-T253G56 Service Manual

Split system air conditioner
Table of Contents

Advertisement

1-2 Major Component Specifications

(A) Indoor Unit

MODEL No.
Source
Remote Controller (Accessory)
Controller P.C.B. Ass'y
Switch Ass'y
Fan (Number...diameter)
Fan Motor
Model...Nominal output
Source
1
No. of pole...r.p.m. (230 V, High)
Coil resistance
(Ambient temperature 20 C)
Safety device
Operating temperature
Run capacitor
Heat exchanger
Coil
Rows...fin pitch
Face area
Auto louver motor
Auto louver motor...Raterd
Coil resistance (at 25 ˚C)
Dew proof heater
SPW-T253G56
RCS - T251G
mm
W
rpm.
BRN – WHT
WHT – VLT
VLT – ORG
Open
C
Close
C
VAC, F
mm
2
m
V, Hz, W, rpm.
220 - 240 VAC, 50 Hz, 3 W, 3.3 rpm. 8P
V, W
– 14 –
1. Specifications
SPW-T253GS56
220 - 230 - 240 V / 1 phase / 50 Hz
RCS - 5PS3E
CR - X363GS
SW - X363GS
Centrifugal (4...ø130)
KFG4Q - 41A5P...40 W
220 - 230 - 240 V / 1 phase / 50 Hz
4...1,198
: 175.1
,
ORG – YEL
:
43.6
,
YEL – PNK
:
27.0
130
5 C
Differential 15 deg. (min.)
440 V, 2.5 F
Aluminum plate fin / Copper tube
3...1.7
0.170
MC8 D
14,900
8 %
240 V, 15 W
:
70.9
:
15.6
SM830043

Hide quick links: