Initialise Printer; Request Software Version; Request Status; Request Analog Voltage - Fujitsu FTP604 User Manual

Controller for fujitsu thermal printers ftp604 series
Table of Contents

Advertisement

3.8.21
[Name]
[Format]
[Description]

3.8.22 Request Software version

[Name]
[Format]
[Description]

3.8.23 Request Status

[Name]
[Format]
[Description]
Bit
Status
0
Near end
1
Paper
2
Temperature
3
Head
4
Paper Jam
5
Rxerror
6
Buffer
7
Always 1.

3.8.24 Request Analog voltage.

[Name]
[Format]
12-02-2003
Page 3-25 of
51

Initialise Printer

Initialise
ASCII
Hex
Decimal
When the printer controller receives this byte a reset of
the printer will be initialised. This command can be
treated even if buffer is full.
Request software version
ASCII
Hex
Decimal
When the printer controller receives this byte the
software version will be transmitted. This command can
be treated even if buffer is full.
Request status
ASCII
Hex
Decimal
When the printer controller receives this byte a status
byte will be transmitted. This command can be treated
even if buffer is full.
The bit definitions is as follows
0
Logic level is low
Present
Not too hot
Closed
No error
No error
Not full.
Analog voltage
ASCII
Hex
SYN
16
22
ETB
17
23
CAN
18
24
1
Logic level is high
Absent
Head too hot to print
Open
Error
Rx error
Full (less than 16 bytes left)
EM
19
- 3-25 -

Advertisement

Table of Contents
loading

This manual is also suitable for:

Prn604-s

Table of Contents