Oki C7500n Maintenance Manual page 111

Color led page printer
Hide thumbs Also See for C7500n:
Table of Contents

Advertisement

Message
Cause
Service Call
Option unit for different
110: Error
model detected.
~
116: Error
110: Envelope
Feeder
111: Duplex unit
112: 2nd Tray
113: 3rd Tray
114: 4th Tray
115: 5th Tray
116: Finisher
Service Call
PU unit fan motor error.
120: Error
Service Call
High-voltage power
121: Error
supply I/F error.
Service Call
Low-voltage power
122: Error
supply fan error.
Low-voltage power
supply temperature error.
Service Call
Improper environment
123: Error
humidity detected by
sensor.
Service Call
Improper environment
124: Error
temperature detected
by sensor.
Service Call
Error detected at MT
125: Error
home position.
Turn power
Sensor dew error.
OFF and wait
126: Dew
error
Service Call
Temperature rise
130: Error
detected at LED head.
Service Call
Same unit not detected
131: Y Head
upon power ON or
132: M Head
opening cover.
133: C Head
134: K Head
Service Call
Error detected at
140: Y ID
proper ID position.
141: M ID
142: C ID
143: K ID
Service Call
When a fuse could not
150: Y
be disconnected in the
151: M
ID unit.
152: C
153: K
Service Call
When belt unit fuse
154: Error
cannot be disconnected.
Service Call
When fuser unit fuse
155: Error
cannot be disconnected.
41955801TH Rev.8
Table 5-1-1 Operator Alarm (3/6)
Error Description
Is a proper option unit for the printer set?
1) Is fan in PU unit operating?
2) Error reoccurs after replacing fan motor.
Is cable between PU board andhigh-
voltage power LSI connected properly?
1) Is fan in low-voltage power supply unit
operating?
2) Error reoccurs after replacing fan motor.
1) Is error message displayed?
2) Does error reoccur?
1) Is error message displayed?
2) Does error reoccur?
1) Is error message displayed?
2) Does error reoccur?
Sensor dew error detected.
1) Is error message displayed?
2) Does error reoccur?
1) Is error message displayed?
2) Is LED head properly set?
3) Does error reoccur?
1) Is error message displayed?
2) Does error reoccur?
Is ID unit set properly?
Is belt unit set properly?
Is fuser unit set properly?
Oki Data CONFIDENTIAL
Solutions
Yes
Set proper option unit.
No
Check connections and turn power
ON. If error is not recovered, replace
the unit.
No
Replace fan motor.
Yes
Replace engine control board.
Yes
Replace engine control board.
No
Connect properly.
Yes
Replace high-voltage power supply.
Check improper connections for
high-voltage.
No
Replace fan motor.
Yes
Replace low-voltage power supply.
Yes
Replace low-voltage power supply.
Yes
Turn ON power again.
Yes
Replace humidity sensor.
Yes
Turn ON power again.
Yes
Replace humidity sensor.
Yes
Turn ON power again.
Yes
Replace MT.
Turn ON power after a while.
Yes
Leave alone for 30 min.
Yes
Turn power OFF. Leave for 30 min.,
Yes
then turn power ON. Replace LED
head.
Yes
Confirm that LED head is set properly.
No
Turn power ON again.
Yes
Replace LED head assembly.
Yes
Turn power ON again.
Yes
Replace drum assembly.
Yes
Check cable connections and replace
engine board.
Yes
Check cable connections and replace
engine board.
Yes
Check cable connections and replace
engine board.
111 /

Advertisement

Table of Contents
loading

This manual is also suitable for:

C7350C7550C7300C7500

Table of Contents