Note:
For transfer of a sector of data, the host needs to read Status register (X'1F7') in order to
clear INTRQ (interrupt) signal. The Status register should be read within a period from the
DRQ setting by the device to starting of the sector data transfer. Note that the host does
not need to read the Status register for the reading of a single sector or the last sector in
multiple-sector reading. If the timing to read the Status register does not meet above
condition, normal data transfer operation is not guaranteed.
When the host new command even if the device requests the data transfer (setting in DRQ
bit), the correct device operation is not guaranteed.
Parameter write
~
BSY
DRDY
DRQ
INTRQ
Data transfer
* The host should receive 512-byte dummy data or release the DRQ set state by resetting.
5.4.2

Data transferring commands from host to device

The execution of the following commands involves Data transfer from the host to the drive.
FORMAT TRACK
WRITE SECTOR(S)
WRITE LONG
WRITE BUFFER
WRITE VERIFY
SECURITY DISABLE PASSWORD
SECURITY ERASE UNIT
SECURITY SET PASSWORD
SECURITY UNLOCK
The execution of these commands includes the transfer one or more sectors of data from the
host to the device. In the WRITE LONG command, 516 bytes are transferred. Following
shows the protocol outline.
Command
Figure 5.3

Protocol for command abort

C141-E077-01EN
Status read
* Transfers dummy data