ELECTRICAL
It is necessary to provide
an appropriate
junction
box as shown on the previous
page. The installation
of
this junction
box and the wiring connecting
it to the house wiring
should be done by a qualified
electrician.
All wiring
must be done in accordance
with
the National
Electrical
Code and/or any other applicable
local
codes or ordinances.
The power supply to the junction
box must be 120/240 volt (or 120/208
for special ordered unit),
60 hertz
A.C.
single phase, 3 wire.
Do not connect
the oven to a D.C. power
supply
as serious damage to the
components
will
result. Refer the TABLE
1 for fuse or circuit
breaker size for the model being installed.
Remember
that the oven must have a separate circuit.
Do not operate other electrical
equipment
on the
same circuit.
TABLE
1
Model No.
Maximum
Wattage
I
KESO-140/170
I
KESO-145/175
SCO- 1243/l 273
3.8 KW @ 240 V
SCO-243312733
I
KE DO-240/270
I
6.0 KW@ 240 V
KE DO-245/275
SCO-224312273
7.5 KW @ 240 V
SCO-244312743
Fuse or Breaker
Size Required
30 AMPS
40 AMPS
UNPACKING
THE UNIT
The oven should
be left on the carton
base until
it is ready to
put into the cabinet.
It is also recommended
that the pads over
the door(s)
be left in place. These precautions
will
reduce the
possibility
of damage to the front of the unit and the bottom
of
the front frame.
Prior to installation,,
,test the electrical
service to assure that it
agrees with the specrfrcations
on the oven data plate.
Remove all cords, tape and wire used to hold various parts in
position
during shipment.
Remove oven racks from the inside of
the oven and put to one side while
oven is being installed
in
cabinet.
Take broiler
pan and grid from packing
on top of the
oven and keep with
literature
packet in a location
where they
will be retained by the owner.
ELECTRICAL CONNECTION
4
;I:/
-\
i _--&,w
-\I : _ 1 ,. _
7
&\
-'& 2.
, !:w
To Remove Oven Racks
Slide
rack
forward
until
bar on back
of rack
touches
first
stop.
Lift
front
of rack
until
rear
portion
of rack
slides
out between
front
two stops.
WARNING:
ELECTRICAL
AND
GROUNDING
CONNECTIONS
MUST
COMPLY
WITH
THE APPLI-
CABLE
PORTIONS
OF THE NATIONAL
ELECTRICAL
CODE AND/OR
OTHER
LOCAL
ELECTRICAL
CODES.
WARNING:
DISCONNECT
ELECTRICAL
POWER SUPPLY
AND
PLACE
A TAG
AT THE
DISCON-
NECT SWITCH
INDICATING
THAT
YOU ARE WORKING
ON THE CIRCUIT.
Connect
the conduit
from the oven to the junction
box and properly
connect
to the power supply
leads.
GROUNDING
-THE
OVEN MUST BE GROUNDED,
Do not work on the oven wiring
until the oven has been positively
grounded.
The oven frame is grounded
through
the base grounding
wire. Connect
it to ground in accordance with local
codes. Connect the white neutral to the service neutral wire at the junction
box.