Page 1
OPERATION MANUAL FTB-350A 24V TEST BOX Frymaster, L.L.C., 8700 Line Avenue Shreveport, LA 71106 TEL 318-865-1711 FAX 318-868-5987 24-Hour Service Hotline 1-800-551-8633 APRIL 11 *8196797*...
TABLE OF CONTENTS INTRODUCTION PARTS ORDERING PARTS LIST CONTROL PANEL DIAGRAM F3000 TEST PROCEDURE Legacy Fryers F3000 TEST PROCEDURE HP580/590 Electric F3000 TEST PROCEDURE HP690 Gas F3000 TEST PROCEDURE Pitco Fryers Page #...
INTRODUCTION The FTB-350A Test Box is a tester designed to test the F3000 Frymaster cooking controller for correct operating and controlling functions. WARNING: This test box should not be hooked up to 12V controllers. PARTS ORDERING Parts orders must be placed directly with your local Factory Authorized Servicer. If you do not have a Factory Authorized Servicer list, please contact Frymaster Service Department at 1-800-551-8633 or 1-318-865-1711.
Item Part Number Kit, FTB350A, 120V/24V F3000 Test Box (Includes cable and 826-2978 transformer assembly.) 108-3342 Test Box FTB-350A 120V/24V Domestic 108-3345 Transformer Assembly 120V/24V Domestic 807-5285 Cable Assembly, F3000 Cable PARTS LIST Description...
Right Probe/Thermistor Switch Simulates Temperature Left Variable Control Right Variable Control 10. ON/OFF Switch Power To FTB-350A Test Unit 11. HP690 Power Switch Power to FTB-350A Test Unit and controller when set to HP690. 12. HP690 Alarm Switch Simulates Alarm Signal Input...
F3000 TEST PROCEDURE FOR LEGACY FRYMASTER FRYERS (KJ3, 118G, H55, MJ45, 118E/RE80 and FPRE114/117) Ensure the controller is set to LEGACY-FRYMASTER using code 7628 in tech mode. With the Controller displaying OFF press and hold the check button until PRODUCT SETUP is displayed.
Page 7
TEST CONTROLLING FUNCTION Press controller ON/OFF switch to ON (set point = 340°F/171°C). Set FTB-350A PROBE switches (6 & 7) to VARIABLE. (a) RELAY POWER indicator (3) illuminates. (b) Rotate VARIABLE knob (8 & 9) counterclockwise until controller indicates a temperature.
See page 6 for instructions to run initial test set-up. TEST POWER TO FRYER INTERFACE BOARD See page 6 for instructions to test power to fryer interface board. TEST MELT-CYCLE FUNCTION See page 6 for instructions to test melt-cycle function.
240VAC outlet. Set controller up as follows: (a) Set POWER switch to OFF. (b) Connect FTB-350A 16-pin connector to rear of controller. Plug 4-pin drain switch into connector. (d) Switch the HP690 POWER switch (11) to ON. (e) Switch the HP690 ALARM switch (12) to OFF.
Page 10
Turn power off switching the HP690 POWER switch (11) to OFF. TEST MELT-CYCLE FUNCTION Switch the HP690 POWER switch (11) to ON. Set FTB-350A PROBE switch (7) to 3°C/37°F. RELAY POWER indicator (3) illuminates. HEAT indicator (4) should cycle on and off. “MLT-CYCL” is displayed on the controllers alternating with setpoint on the left and actual temperature on the right.
Page 11
TEST PRESSURE SOLENOID ACTIVATION See page 8 for instructions to test solenoid activation. TEST STRATIFY FUNCTION Turn on FTB-350A POWER switch (10) (set point = 340°F/171°C). Set FTB-350A PROBE switch (7) to variable. Set HP 690 ALARM switch (12) ON.
NON-CE. Press the right arrow. Set system type to PITCO. Press the right arrow. Set ENERGY to ELEC or GAS. Press the right arrow. Set TYPE to fryer type desired. Press the right arrow. Set FRESH OIL to NONE. Press the right arrow. Set WASTE OIL to NONE.
Page 14
Frymaster, L.L.C Shipping Address: 8700 Line Avenue, Shreveport, Louisiana 71106 TEL 1-318-865-1711 FAX (Parts) 1-318-219-7140 FAX (Tech Support) 1-318-219-7135 SERVICE HOTLINE 819-6797 PRINTED IN THE UNITED STATES APRIL 11 1-800-551-8633...