Samsung SCH-A302 Service Manual page 5

Cellular phone
Hide thumbs Also See for SCH-A302:
Table of Contents

Advertisement

2-3. RECEIVER
Rx Sensitivity and Dynamic Range
Conducted Spurious Emission
869 ~ 894 MHz
824 ~ 849 MHz
All other Frequencies
Single Tone Desensitization
Rx Power level -101 dBm
Tone Power level -30 dBm
Tone Offset from Carrier ± 900 kHz
Intermoculation Spurious Response Attenuation
Tone 1 offset from carrier = ± 900 kHz
Tone 2 offset from carrier = ± 1,700 kHz
-Test 1, 2
Rx power = -101 dBm
Tone 1 power = -43 dBm
Tone 2 power = -43 dBm
-Test 3, 4
Rx power = -90 dBm
Tone 1 power = -32 dBm
Tone 2 power = -32 dBm
-Test 5, 6
Rx power = -79 dBm
Tone 1 power = -21 dBm
Tone 2 power = -21 dBm
SAMSUNG Proprietary-Contents may change without notice
-104 dBm, FER=0.5 % or less
-25 dBm, FER=0.5 % or less
< -81 dBm
< -61 dBm
< -47 dBm
Lower than 1 %
Lower than 1 %
1-3
SCH-A302
Specification

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents