2-7 AMPS Debug Display Information
To select debug display mode : Press [MENU] + [0] + [0], and press [0] + [4] + [0] + [7] + [9] + [3], and press [1].
1
SIDxxxxx
2
PWRx
RSSIxxx
SATx
3
xx
xx
8
7
4
x
x
5
CHxxxx
6
SAMSUNG Proprietary-Contents may change without notice
1 SIDxxxxx : AMPS Home System ID
2 PWRx : Power Level 0 ~ 7
3 SATx : Supervisory Audio Tone code (0 ~ 2)
4 x (Using Frequency Band) : A Band or B Band
5 RSSIxxx : RSSI value
6 CHxxx : Channel number
7 Handset Status : 1 - Initialization state
8 System acquisition state
2-10
Specification
2 - Idle state
3 - System Access state
4 - Voice channel state