Download Print this page

Whirlpool 761883306 Installation Instructions Manual page 4

30/36" convertible range hood

Advertisement

Injury Hazard
More than one person is required
to help
with installation
because
of the weight
and
size of range hood.
Failure to follow this instruction
could
result in serious
injury.
keyhole
slot
front
of hood
8
w
n
Lift the range hood into final
position
and center.
Mark on the underside
of cabinet
the location
of the four keyhole
mounting
slots. Set range hood aside on a
protected
surface.
9
I
n
Determine
and clearly
mark a
vertical
centerline
on the wail and cabinet
in the area the vent opening
will be made.
Electrical
Shock Hazard
Take special care when drilling
holes into
the wall.
Contacting
electrical
wires concealed
behind the wall covering
could result in
death or serious
injury.
centerline
10
n
TO wire throuah
totx mark a line
7-l /2" from the right of thz centerline
on the
underside
of the cabinet.
Mark the point on
this line that is l-3/8" from back wall. Drill a
l-1 /4" diameter
hole through
the cabinet
at
this point.
Panel C
Numbers
correspond
to steps.
I
J
I
' '(i
l-3/8 :_._ & _ ,
I-
;*I;
i 7-l/r'
I
\I,
&l-5/8"
(to floor)
I
centerline
t
To wire through
rear, mark a line 7-l J2" from
the right of the centerline
on the wall. Mark
the point on this line that is 64-5/8" from the
floor (or l-3/8" from underside
of cabinet).
Drill a l-l /4" diameter
hole through
wall at
this point.
11
\
n
TO vent through
the roof with 7"
round ductwork,
mark 4-l 72" and 5" in from
back wall along the centerline
on
underside
of cabinet.
Use these points as
centers to draw 7-l J8" circles on underside
of cabinet.
Use a saber saw to cut the
openings
for the ductwork.
Repeat
for the
underside
of the top of the cabinet.
This will
create
slotted openings.
To vent through
the roof with 3-l /4" x 10"
rectangular
ductwork,
mark a line 1" and 5"
from the back wall on the underside
of the
cabinet.
Mark lines 5-1 J4" to the right and
left of the centerline
on the underside
of
cabinet
that connect
the lines just drawn.
Use a saber saw to cut a rectangular
opening
for the ductwork.
Repeat
for the
underside
of the top of the cabinet.
To vent through
wall with 3- l/4" x 10"
rectangular
ductwork,
measure
from floor
65-7/B" and 62-3/a" (or 1 J8" and 3-5/W down
from underside
of cabinet)
and mark on
back wall. Measure
and mark a line 5-l J4"
to right and left of centerline,
connecting
the two lines. Use a saber saw to cut a
rectangular
opening
for the ductwork.
12
n
Install ductwork
through
the
vent opening
in upper cabinet
or wall.
Complete
venting
system according
to
method
needed.
See "Venting
requirements."
Use caulking
to seal exterior
wall or roof opening.
round
13
WAt-tach
rectanaular
damcer
to
selected
rectangular
vent opening.
If
damper
is attached
to back of range hood,
be sure damper
hinge is toward
the top. For
round vented
installations,
use round
damper
in duct to prevent
air from flowing
back into ductwork.
If wall or roof cap has a
damper,
remove
damper
blade
from range
hood.
14
1 Run wiring through
wall or
cabinets
according
to the National
Electrical
Code and local codes and
ordinances.
Do Not turn on power
until
installation
is complete.
keyhole
slot
m
screw
15
n
Start screws throuah
neck of
each
of the four keyhole
mounting
screw
slots marked
on the cabinet
bottom.

Advertisement

loading