Download Print this page

UNI-T UT801 Operating Manual page 2

Bench type digital multimeters

Advertisement

P/N: 110401101618
Warning:
1. Selecting the correct terminal input and turns the
rotary switch to select the measuring function. If fails
to do that, the buzzer beep and the warning signal
flash on.
Range
Alarm Alert On False Terminal Input
V Hz Ω
10A mAμA
mAμA ℃ hFE F
10A
10A
mAμA
2.DC or AC Voltage Measurement
● To avoid harms to you or damages to the Meter
from electric shock, please do not attempt to measure
voltages higher than 1000 V although reading may
be obtained.
T h e M e t e r h a s a n i n p u t i m p e d a n c e o f
10MΩ(exceptUT802/ACV input impedance of 2MΩ)
This loading effect can cause measurement errors in
high impedance circuits and so you need to take a
note on it.
3.DC or AC Current Measurement
● Before connect the Meter in serial with the tested
return circuit, closed
the return circuit current to avoid the dangerous of
sparking.
● Do not use over >10A current measurement.
Although the meter can work on below 20A current
testing but for the avoiding any harms to you or
damages to the Meter.
4.Measuring Resistance, Diodes, Continuity or
Capacitance
● To maintain the measurement accuracy, discount
circuit power and discharge all the high voltage
capacitors during the measuring resistance.
● When measuring high resistance on 1MΩ or
above, it is normal to take several seconds to
obtain a stable reading. In order to obtain stable
reading, choose shorter test lead to carrying out
measurement.
● The test leads and the Meter inside wire will
bring around 0.1Ω~0.2Ω of error to resistance
measurement when measuring low resistance. To
obtain accurate readings in low-resistance, short
–circuit the test leads beforehand and record the
reading obtained, call this reading as X. Then use
the equation: measured resistance value (Y) – (X) =
accurate readings of resistance.
● During measurement, Diodes is in a good silicon
junction drops between 500mV~800mV as the
normal value. The continuity measurement, the poles
between resistance is >100Ω. it is a short circuit, but
on the poles between resistance is ≤10Ω, it is a good
connection, buzzer is continually beep on, and the
reading value is nearly to the circuit resistance value,
Unit is Ω.
Accuracy Specifications
Accuracy: ±(% reading + digits), guarantee for 1 year
Operating temperature: 18℃~28℃
Environmental humidity: Less than 75%RH
1. DC Voltage
Range
Resolution
Accuracy Tolerance:±(% Reading+Digits)
UT801
UT802
UT801
200mV 0.1mV
0.01mV
2V
1mV
0.1mV
20V
10mV
1mV
±(0.5%+2)
200V
100mV
10mV
1000V
1V
0.1V
±(0.8%+3)
Input Impedance: is average on 10MΩ
Maximum Voltage Input: 1000V (Except 200mV,
250V)
2. AC Voltage
Range
Resolution
Accuracy Tolerance:±(% Reading+Digits)
UT801
UT802
UT801
2V
1mV
0.1mV
±(0.8%+3)
±(0.5%+20)
20V
10mV
1mV
±(0.8%+40)
200V
100mV
10mV
±(1.0%+4)
1000V 1V
0.1V
Input Impedance: UT801 is average on 10MΩ ,
UT802 is about 2MΩ .
Maximum Voltage Input: 750Vrms
Frequency: 45Hz~400Hz
Display: True RMS
3. DC Current
Range
Resolution
UT801 UT802
200μA
0.1μA
2mA
1μA
20mA
10μA
200mA
0.1mA 0.01mA
10A
10mA
* When ≥5A, Continuous measurement less than 10
seconds at an interval more than 15 minutes.
4. AC Current
Range
Resolution
UT801
UT802
2mA
1μA
0.1μA
20mA
10μA
200mA 0.1mA
0.01mA
10A
10mA
Frequency: 45Hz~400Hz
* When ≥5A, Continuous measurement less than 10
seconds at an interval more than 15 minutes.
5. Resistance
Range
Resolution
UT801
200Ω
0.1Ω
0.01Ω
2kΩ
20kΩ
10Ω
200kΩ 100Ω
2MΩ
1kΩ
100Ω
20MΩ
10kΩ
200MΩ
When >100
purpose.
6. Capacitance
Range
Resolution
UT801 UT802
20nF
10pF
2μF
1nF
100pF
200μF* 100nF 10nF
*>40μF capacitance measurement as reference
purpose.
7. Frequency
Range
Resolution
UT801 UT802
2kHz
1Hz
200kHz 100Hz 10Hz
Input Amplitude a:
(2kHz range)
(200kHz range)150mV≤a≤30Vrms
UT802
±(0.1%+5)
8. Temperature
R
ange
Resolution
±(0.1%+3)
UT801 UT802
-40~-20℃
±(0.2%+5)
>-20℃0℃
1℃
>0~100℃
>100~1000℃
* Thermocouple: It is suitable to use K type
thermocouple. This include point contact K type
thermocouple can only be used on less than 230℃
temperature measurement.
UT802
9. Diode Test
Range Resolution
UT801 UT802
1mV
0.1mV
Accuracy Tolerance:±(% Reading+Digits)
UT801
UT802
0.01μA
0.1μA
1μA
±(0.8%+2)
±(0.5%+20)
1mA
±(2.0%+4)
±(1.5%+40)
Accuracy Tolerance:±(% Reading+Digits)
UT801
UT802
1μA
±(1.0%+3)
±(0.8%+40)
1mA
±(2.5%+5)
±(2.0%+40)
Accuracy Tolerance:±(% Reading+Digits)
UT802
UT801
UT802
0.1Ω
±(0.8%+3)
±(0.5%+10)
10Ω
±(1.2%+5)
10kΩ
±(5%+40)
resistance measurement as reference
Accuracy Tolerance:±(% Reading+Digits)
UT801
UT802
1pF
±(4%+3)
±(4%+10)
±(5%+5)
±5%+10)
Accuracy Tolerance:±(% Reading+Digits)
UT801
UT802
0.1Hz
±(1.5%+5)
±(1.2%+10)
50mV≤a≤30Vrms
Accuracy Tolerance:±(% Reading+Digits)
UT801
UT802
-(8%+5)
-(8%+40)
±(1.2%+4)
±(1.2%+30)
0.1℃
±(1.2%+3)
±(1.2%+25)
±(2.5%+2)
±(2.5%+20)
Remarks
Open circuit voltage is around 3
V, Silicon junction drops between
0.5~0.8V as the normal value.
Operating Manual
UT801/802
10. Continuity Test
Range
Resolution
Remarks
UT801 UT802
O p e n c i r c u i t v o l t a g e i s
1Ω*
0.1Ω*
approximate 3V
When circuit disconnected with resistance value
>100Ω, buzzer does not beep.
When circuit is in good connection with resistance
value ≤10Ω, buzzer beeps continuously.
11. Transistor hFE
Range
Resolution
Remarks
Ib0 is about 10μA, Vce is
UT801 UT802
hFE
about 2.5V
1β*
0.1β*
Replacing the battery(see Diagram 4)
R14 1.5V*6
Diagram 4
Specifications and other information shown on this
instruction manual are subject to change without
notice
Development District,Hu Men Town,Dong Guan City,
Guang Dong Province,China
adapter
Power
Fuse