IMPORTANT
IMPORTANT
• Discard all ice produced in the first harvest.
• Should power to the unit be interrupted during the
self-clean cycle, it will be necessary to repeat the
complete cleaning cycle after power is restored.

Refresh Kit

Due to variations in water quality or inadequate maintenance your
unit may become excessively coated in lime scale or calcium.
U-Line offers a cost effective refresh kit which replaces many
interior components and will return your unit to like new
condition. Refresh kits may be ordered from your local distributor
and installed by your local service company. For information on
your local distributor or service company please visit
http://www.u-lineservice.com.
Refresh Kit Part Number
Model
Part Number
CLR2160
80-51003-00
CLRCO2175
80-51002-00

Ice Cube Thickness Adjustment

Interval - As Required
Ice thickness adjustments are made using the control panel as
follows:
1. To enter the thickness adjustment mode:
• Touch and hold WARMER
• Touch and release COOLER
WARMER
.
• The display will switch to "0" to confirm the thickness
adjustment mode has been selected.
2. The factory setting is "0," and the total range of adjustment is -5
to +5 (ideal range is -1 to +1). Use WARMER
setting and thicken the ice bridge, or COOLER
setting to thin the ice bridge.
IMPORTANT
IMPORTANT
Ice thickness adjustment should only be made one
increment at a time. Allow ice maker production to
stabilize for 24 hours before rechecking ice thickness.
3. Touch and release the LIGHT button key to exit the ice
thickness adjustment mode.
4. Remove all ice from the storage bin.
7
.
three times, then release
to raise the
to lower the
U-Line Ice Maker
Ice cubes in any given batch will vary, so it is necessary to choose
cubes from the sample area for comparison when making
adjustments. If further adjustments are desired, repeat Steps 1
through 4.
The ice cube thickness is factory set for best overall performance.
The factory setting is designed to maintain an ice bridge of
approximately 1/16" to 1/8" under normal conditions, resulting in a
dimple of approximately 1/4" to 1/2" in depth. A fuller cube with
less of a dimple results in a thicker ice bridge. As the ice bridge
becomes thicker, the tendency for the cubes to stay together as a
slab increases. A bridge thicker than 1/8" may cause cubes to
overfill the ice bucket.
ICE BRIDGE
Ice Bridge and Dimples
1/4" TO 1/2"
DIMPLE
BRIDGE
TOO THIN
DIMPLE
TOO DEEP
DIMPLES
Cube Types
1/16" TO 1/8"
ICE BRIDGE
GOOD
BRIDGE
TOO THICK
LITTLE OR
NO DIMPLE
BAD

Hide quick links:

Advertisement

Table of Contents
loading