Operation Tips - Frigidaire FSC09CH7M Owner's Manual

Frigidaire air conditioner user manual
Table of Contents

Advertisement

Operation
tips
The following
events may occur during normal operation:
Protection
of the air conditioner
Compressor
protection:
The compressor
can't restart for 3 minutes after it stops.
Anti-cold
air (Cooling and heatinq models only2L.
The unit is designed
not to blow cold air on HEAT mode, when the indoor heat
exchanger
is in one of the following three situations
and the set temperature
has
not been reached.
1. When heating has just starting.
2. Defrosting.
3. Low temperature
heating.
Defrosting
(Cooling and heating models only):
Frost may be generated
on the outdoor
unit during heat cycle when outdoor
temperature
is low and humidity is high resulting in lower heating efficiency
of
the air conditioner.
During this condition
air conditioner
will stop heating operation
and start
defrosting
automatically.
The time to defrost may vary from 4 to 10 minutes according
to the outdoor
temperature
and the amount of frost buildup on the outdoor
unit.
The indoor or outdoor
fan stop running when defrosting
(Cooling and heating
models only).
A white mist coming out from the indoor unit
A white mist may generate
due to a large temperature
difference
between air
inlet and air outlet on COOL mode in an indoor environment
that has a high
relative humidity.
A white mist may generate
due to moisture generated
from defrosting
process
when the air conditioner
restarts in H EAT mode operation
after defrosting.
Low noise of the air conditioner
You may hear a low hissing sound when the compressor
is running or has just
stopped
running. This sound is the sound of the refrigerant
flowing or coming to
a stop.
You can also hear a low "squeak"
sound when the compressor
is running or has
just stopped
running. This is caused by heat expansion
and cold contraction
of
the plastic parts in the unit when the temperature
is changing.
A noise may be heard due to louver restoring to its original position
when power
is first turned on.
,..j
Dust is blown
out from the indoor
unit
This is a normal condition when the air conditioner
has not been used for a long
time or during first use of the unit.
A peculiar smell comes
out from the indoor unit
This is caused by the indoor unit giving off smells permeated
from building
material, from furniture,
or smoke.
Dripping
water may generate
on the surface
of the indoor unit when
cooling
in a high relatively
humidity
(relative
humidity
higher than 80%)
Adjust the horizontal
louver to the maximum air outlet position and select HIGH
fan speed.
The air conditioner
turns to FAN only mode from COOL or HEAT (For
cooling
and heating models
only) mode
When indoor temperature
reaches the temperature
setting on air conditioner,
the
compressor
will stop automatically,
and the air conditioner
turns to FAN only
mode. The compressor
will start again when the indoor temperature
rises on
COOL mode or falls on HEAT mode (For cooling and heating models only) to the
set point.
Heating
mode (For cooling
and heating models
only)
The air conditioner
draws in heat from the outdoor unit and releases
it via the
indoor unit during heating operation.
When the outdoor temperature
falls, heat
drawn in by the air conditioner
decreases
accordingly.
At the same time, heat
loading of the air conditioner
increases
due to larger difference
between
indoor
and outdoor temperature.
If a comfortable
temperature
can't be achieved by the
air conditioner,
we suggest you use a supplementary
heating device.
Auto=restart
function
Power failure during operation
will stop the unit completely.
For the unit without Auto-restart
feature, when the power restores, the
OPERATION
indicator on the indoor unit starts flashing. To restart the operation,
push the ON/OFF button on the remote controller. For the unit with Auto-restart
feature, when the power restores, the unit restarts automatically
with all the
previous settings preserved
by the memory function.
Lightning
or a car wireless
telephone
operating
nearby
may cause
the unit
to malfunction
Disconnect
the unit with power and then re-connect the unit with power again.
Push the ON/OFF button on the remote controller to restart operation.