Led Indicators - Axis P1347 User Manual

Hide thumbs Also See for P1347:
Table of Contents

Advertisement

AXIS P1347 Network Camera
Hardware overview
Digital output — For connecting external devices such as relays and LEDs. Connected devices can be activated by
the VAPIX® Application Programming Interface, output buttons on the Live View page or by an Action Rule. The
output will show as active (shown under System Options > Ports & Devices) if the alarm device is activated.
Digital input — An alarm input for connecting devices that can toggle between an open and closed circuit, for
example: PIRs, door/window contacts, glass break detectors, etc. When a signal is received the state changes and
the input becomes active (shown under System Options > Ports & Devices).
Function
GND
3.3 V DC Power
Digital Input
Digital Output

LED indicators

LED
Color
Network
Green
Amber
Unlit
Status
Green
Amber
Red
Pin
Notes
1
Ground
2
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
3
Connect to GND to activate, or leave floating (unconnected)
to deactivate.
4
Internal connection to ground when activated, floating
(unconnected) when deactivated. If used with an inductive
load, e.g. a relay, a diode must be connected in parallel with
the load, for protection against voltage transients.
3.3 V max 50 mA
Indication
Steady for connection to a 100 MBit/s network. Flashes for network activity.
Steady for connection to a 10 MBit/s network. Flashes for network activity.
No network connection.
Steady green for normal operation.
Steady during startup and when restoring settings.
Slow flash for failed upgrade.
1
2
3
4
7
Specifications
Max load = 50 mA
0 to +40 V DC
Max load =100 mA
Max voltage = +40 V DC