Instructions For Removing From Wall; Surface Mount; Figure; It Can Be Re-Placed In The Same Location When Service Is Complete. (Figure - Dimplex BLF50 Service Manual

Hide thumbs Also See for BLF50:
Table of Contents

Advertisement

Figure 6

19
1
2
(49.5 cm)
9.
Proceed to the instructions within this manual relating

to the repair being performed - see Table of Contents

for page number.

INSTRUCTIONS FOR REMOVINg FROM
WALL

WARNINg: Disconnect power before attempting any

maintenance or cleaning to reduce the risk of electric

shock or damage to persons.

CAUTION: If unit was operating prior to servicing allow

at least 10 minutes for lights and heating elements to cool

off to avoid accidental burning of skin.

!

NOTE: Only required for replacement of the power

cord or removal from service.

CAUTION: Follow "Preparation for Service" instructions

before proceeding.

Mounting - The fireplace may be mounted in one of 3 meth-

ods:

Surface Mount

Recess Mount (partially in the wall)

Flush Mount (completely in the wall)

Identify the type of mounting and follow the appropriate

instructions in the following pages. (See Figure 6 for the

top and side profile view with measurements of the back

panel).

CAUTION: Two people will be required for removal
and re-installation of the fireplace. The unit is approx. 50
5/16"w x 19 1/2"h x 7"d. Weight is approximately 75lbs.
CAUTION: To prevent injury or damage, turn off the
breaker in your electrical panel prior to attempting to re-
move this unit off the wall.
!
NOTE: If fireplace is hard wired directly to the electri-
cal panel, and there is not enough slack in the wires within
the wall to reach your work area, remove the electrical junc-
tion box cover located on the bottom right by removing the
1 screw on the front of the cover. Lift the cover off and set
aside. Disconnect the 3 wire connectors connected to the
1
48
" (123 cm)
2
46" (116 cm)
50
5
" (128 cm)
16
power source, taking note of their original configuration.
Surface Mount
(Figure 7)
Tools Required: Philips head screwdriver
CAUTION: Follow "Preparation for Service" instructions
before proceeding.
1.
!
openings were used for positioning the fireplace so that
it can be re-placed in the same location when service is
complete. (Figure 7)
2.
Figure 7
3" (7.6 cm)
(17.8 cm)
Partially unscrew the rear mounting screws that are
holding the fireplace to the wall along the back panel
of the unit. Support the weight of the fireplace when
loosening the screws so unit does not fall off the wall
unexpectedly.
NOTE: Be sure to take note of which keyhole mount
Take the fireplace off the wall by carefully lifting the
fireplace off the mounting screws so they line up to the
larger part of the keyhole openings and pull forward.
Carefully lay the unit down on a solid flat surface with
the front of the unit facing up.
Permanent
mounting hole
7"
16"
18"
(40.6 cm)
(45.7 cm)
13
3
"
16
(9.7 cm)
Wall stud
Key-hole
7