System Installation Guide
Indoor sensor operation
Wireless indoor sensor
Battery level indicators (when batteries are inserted)
Good: Status light flashes green for 5 seconds.
Low: Status light flashes red for 5 seconds. Use fresh batteries.
Battery level indicators (during use)
Good: Status light remains off.
Low: Battery power will be depleted in about 2 months. Thermostat displays Low Battery warning. Status light
remains off.
Critical: Battery power will be depleted in about 3 weeks. Status light flashes red.
The thermostat can use up to 6 optional wireless sensors.
69-2490—03
69-2490_B.indd 24

Temperature control

The thermostat can be set to respond to its
internal temperature sensor, or to an option-
al remote indoor sensor. If multiple sensors
are used, the thermostat will respond to an
average of temperatures detected at each
sensor.
Humidification control
If optional remote indoor sensors are
installed, you can choose which sensor you
want to use for humidification control. You
can use a different sensor for dehumidifica-
tion.
Dehumidification control
If optional remote indoor sensors are
installed, you can choose which sensor
you want to use for dehumidification con-
trol. For example, you can use one sensor
for humidification control, and another for
dehumidification.
24