Electrical Connection
The electric cooktops are not fitted with a power supply
cord because the type of cord used depends on the
connection to the mains (see the wiring diagram below).
To connect the cable, proceed as follows:
Open the terminal box by removing the "V" screw and
taking off the cover.
V
Voltage and frequency of electrical power supply:
220-230/380-400V 3N~ 50/60Hz 5600W
Connect the wires as shown in the diagram.
H05RR-F 5x1.5 CEI-UNEL 35363
H05RR-F 4x1.5 CEI-UNEL 35363
H05RR-F 3x2.5 CEI-UNEL 35363
Fix the cable in place with the "F" cable clamp, close the
lid and fasten it with the "V" screw.
Electrical Connection for Gas Cooktop
Fit the supply cord with a standard plug for the demand
rate indicated on the rating plate or connect it directly to
the electrical mains. In the latter case, a single pole switch
must be placed between the appliance and the mains,
with a minimum opening between the contacts of 3 mm in
compliance with current safety codes (the earthing wire
must not be interrupted by the switch). The power supply
cord must be positioned so that it does not reach a tem-
perature in excess of 50°C above room temperature at
any point.
Before making the actual connection, make sure that:
The fuse and electrical system can withstand the load
required by the appliance;
That the electrical supply system is equiped with an
efficient earth hook-up according to the norms and
regulations prescribed by law;
That the plug or switch is easily accessible.
N.B: Never use adaptors, shunts or the like because they
could overheat or cuase burns.
Attention: If the appliance is installed above a built-in
oven, the electrical connection for the cooktop must be
independent of that for the oven not only for safey reasons,
but also to facilitate removable of the oven in the future.

Technical Information

This appliance complies with the following European
Economic Community directives:
-
73/23/EEC of 19/02/73 (Low Voltage) and subsequent
modifications;
-
89/336/EEC
Compatibility) and subsequent modifications;
-
93/68/EEC of 22/07/93 and subsequent modifications.
9
1
380-400V 3N~
R
1
380-400V 2N~
1
220-230V 1N~
of
03/05/89
2
3
4
5
T
S
N
2
3
4
5
R
S N
4
3
5
2
N
R
(Electromagnetic

Advertisement

loading