Functions Setting Up - Aiphone GT-AC Installation And Operation Manual

Access control keypad module
Table of Contents

Advertisement

FUNCTIONS SETTING UP

This section explains the settings of each function, including the master code for management, the user code for unlocking, the
buzzer and the LEDs.
About the setting mode:
Enter master code twice to switch to the setting mode, and enter the following setting code to perform the settings
for the desired function. After settings have been made, enter the following setting codes to continue the setting
operation. Press
to exit the setting mode.
Setting the code length
Change the length of the master code and the user code.
)They both must be the same length.
Setting the master code
Enter a master code using between 4 and 6 digits (alpha or numeric) to
switch to the setting mode.
) The number of digits in the code can be set by setting the code length.
Setting the code for user group 1
Set the unlocking code for user group 1.
) The number of digits in the code can be set by setting the code length.
Setting the code for user group 2
Set the unlocking code for user group 2.
) The number of digits in the code can be set by setting the code length.
Setting the key illumination time
Set the length of time that the keys will be lit up after they are pressed.
Setting the relay 1 output time
Set the output time of relay 1.
Setting the relay 2 output time
Set the output time of relay 2.
Reset Settings
Return all the settings to their default values.
External output setting
The alarm or security system connected to the terminal of relay 2 will be
activated when the "Lockout" * or the forced entry* is carried out.
* "Lockout": Refer to VIII below. *Forced entry: This function is linked with
the door open/close sensor (N.C.) which is connected to PB2 and C, and
carried out when opening the door without activating this unit. (For example,
entry in an improper manner, manual unlock, etc.)
) If there is a way to open the door without activating this unit, such as
manual unlock, do not make the external output setting for the forced entry.
Lockout
If several incorrect access codes are attempted, the code input function is
disabled for a programmed period of time.
· When "Lockout" is activated, the LED (Orange) indicator and the keypad
blink, and the buzzer sounds for 3 seconds. This is just a sound to inform
you that the function has been activated. It is not a warning sound. If you
want a warning to be sounded, please use the external output function to
activate a commercially-available alarm device.
· The unlock function will work when the request to exit/entry button is
pushed, even while the "Lockout" function is operating.
Auto-relock (Anti-tailgate)
After the door has been linked to the door open/close sensor (N/C), and
unlocked, it will relock itself one second after being closed, thus preventing
the entry of an unauthorized third party.
Timer-linked unlocking setting
The system can be set to unlock the door by pressing the
the set time and linking it to the external timer (N/O). The operations for the
LEDs and the buzzer after unlocking are the same as those used to perform
user code unlocking. When the door is linked to the timer, unlocking can be
performed using the user code and the request to exit/entry button. When
latch output is performed for the relay settings, the relay turns ON/OFF
every time the
key is pressed.
Operation tone settings
Set the tone heard when the keypad is being used to ON/OFF.
• The setting can be saved even when the power is off.
• The system cannot be switched to the setting mode while the relay is unlocked.
• When the setting mode has been activated and no operations are performed for approximately 120 seconds, the system
will exit the setting mode. (If a key is pressed during that time, the timer will start over.)
• Neither the request to exit/entry button nor the timer-linked unlocking
user code cannot be performed while the setting mode is activated.
• The volume (the check tone, operation tone, etc.) from the main unit may become lower according to the mounting status.
: When the auto-relock is used, the request to exit/entry button for relay 2 cannot be used. The output of relay 2 is
1
6
only possible when user code unlocking is performed.
Setting items
)1
key within
Allowable setting range
4, 5, or 6 digits
1
Valid keys: 0 - 9, A, B
Number of codes: 60
Valid keys: 0 - 9, A, B
Number of codes: 40
Valid keys: 0 - 9, A, B
Illumination time: 10 to 99
seconds, or continually lit
Output time: 1 to 99
seconds, or latched
Output time: 1 to 99
seconds, or latched
-
· OFF
· During Lockout
· During forced entry output
· During lockout and forced
entry output
ON/OFF
Invalid number of times:
10 to 99 times
Invalid time:
10 to 99 seconds
ON/OFF
Linked relay: relay 1
relay 2
relay 1 and 2
0 key illumination: ON/OFF
ON/OFF
key can be operated, and unlocking using the
Default value
Setting code
4 digits
1234
-
-
-
-
10 Sec.
3 Sec.
3 Sec.
-
OFF
OFF
OFF
Linked relay: relay 1
0 key illumination: OFF
ON

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents