Electric heating relay

Advertisement

WHEN INSTALLING THIS PRODUCT . . .
1. Read these instructions carefully. Failure to
follow them could damage the product or cause a
hazardous condition.
2. Check the ratings given in the instructions and on
the product to make sure the product is suitable for your
application.
3. Installer must be a trained, experienced service
technician.
4. After installation is complete, check out product
operation as provided in these instructions.
I
Disconnect power supply before wiring to prevent
electrical shock or equipment damage.
All wiring must comply with applicable codes and
ordinances. Be sure the power supply voltage agrees with
the rating on the relay label.
Fig. 3 shows a typical installation within a compart-
ment enclosure on the end of a baseboard heater. The
back of the compartment enclosure should be equipped
with embossing to clear mounting screws.
(Fig. 4) or junction box.
1. Fasten relay securely to mounting surface using
the 2 mounting holes in the backplate or the conduit
bushing.
Disconnect the power supply.
2.
FIG. 3–TYPICAL INSTALLATION ON BASEBOARD
HEATER.
I
FIG. 4–FOUR RELAYS MOUNTED ON WIREWAY.
JUNCTION BOX
4
RED
PROTECTION AS REQUIRED.
FIG. 5–R841C INTERNAL SCHEMATIC AND CON-
NECTION DIAGRAM FOR ONE RELAY.
n
L2 ~
BLACK BLUE
LOW VOLTAGE
THERMOSTAT
n
RED
RESISTANCE
HEATER