"SLEEP Timer"
Pressing this button starts the timer mode that will stop the operation after the setting time.
Press the "SLEEP" button during the operation.
The setting time repeats the following mode by pressing the button:
Continuous operation (Sleep Operation: OFF). The operation stops after passing
the setting time.
Sleep Timer features
During Cooling Operation
The setting temperature rises 0.6°C after 30 minutes of Sleep Timer ON, and rises
0.6°C again after 30 minutes of the first temperature rise.
During Heating Operation
The setting temperature drops 0.6°C after 30 minutes of Sleep Timer ON, and
drops 0.6°C again after 30 minutes of the first temperature drop.

Emergency and test operation

Emergency Operation
The emergency operation is needed only when the remote control can not be used.
When you press the Emergency Operation Switch, you will hear a beep and the emergency operation
starts.
Emergency operation is preset for the following two modes, only based on the temperature of the
room at the time of operation.
Operation
Temperature
mode
Above 23°C
Cooling
Below 23°C
Heating
N O T E
Emergency operation at the temperature between above 23°C and below 26°C just switch the
machine in operation in "cooling mode" without actually "cooling". It is not possible to operate
in "Dry" mode.
4
32
Designated
Timer mode
temperature
26°C
Continuous
23°C
Continuous
Air flow
Automatic
Automatic