Mounting and connecting hour meter

Advertisement

Quick Links

User's
Manual
TS Series (square face)
Select the mounting configuration from below to determine panel cutout size. Then see opposite page for
outline dimensions.
Model TS-xxxxAx (No bezel-use outline 1, if bezel ordered- use outline 2 or 3).
Model TS-xxxxCx (use outline for mounting option C).
Model TS-xxxxDx (no cutout required. This mounts on DIN rail).
Model TS-xxxxFx (use outline 1 only).
Model TS-xxxxGx (No bezel-use outline 1, if bezel ordered-use outline 2 or 3).
TR Series (round face)
Select mounting configuration below to determine panel cutout dimensions. Then see opposite page for
outline dimensions.
Model TR-xxxxAx (use outline for mounting option A).
Model TR-xxxxCx (use outline for mounting option C).
Model TR-xxxxHx (use outline for mounting option H)
Electrical Wiring
If you have selected combination terminals, or will use the screw terminals for connection, please
observe the following precautions:
1) Use AWG #20 to #26 stranded wire
2) Make sure wire is stripped back 3/8" and wire strands are twisted tight or soldered
3) Loosen non-captive screw no more than 5 full turns
4) Insert wire between pin and clip, then tighten securely,
If you are using the pin connection. Use a 1/4" quick connect female spade lug that has been properly
crimped to wire leads. Slide all the way onto the pin terminal.
Please observe polarity symbols molded into case above terminals.
Mounting and Connecting
TR and TS Hour Meters
Yokogawa Corporation of America
2 Dart Road Newnan, Georgia U.S.A. 30265
Tel: 1-800-258-2552 Fax: 1-770-254-0928
IM 61A00A-01E-A
©Copyright May 1, 2003
1st Edition 5/1/03 1M

Advertisement

loading

Summary of Contents for YOKOGAWA TR

  • Page 1 Select mounting configuration below to determine panel cutout dimensions. Then see opposite page for outline dimensions. Model TR-xxxxAx (use outline for mounting option A). Model TR-xxxxCx (use outline for mounting option C). Model TR-xxxxHx (use outline for mounting option H)
  • Page 2 Mounting A Cutout 51mm diameter (2.01”) 50.5+1 Anti-vibration boot and clamp Mounting C Cutout 71mm diameter (2.80”) for TR and TS (square outline not shown) 71+2 Three screw front mounting for TR Series Mounting H Cutout 58mm diameter (2.28”) 64.3...

This manual is also suitable for:

TsTs seriesTr series