Table 2-2. Display Screen--Descriptions (cont.)
Center box with temperatures—Center 50 by 50 pixel box with the
N
maximum, average, and minimum temperatures in the box (when
enabled).
Hot cursor temperature—Temperature and location of the hottest
O
temperature in the image; always in red (when enabled).
Cold cursor temperature—Temperature and location of the coldest
P
temperature in the image; always in blue (when enabled).
Analysis point—Temperature of marker point in the image. You can add
Q
up to three marker points (when enabled).
Analysis area—Min., avg., and max. temperatures of the marker area in
R
the image. You can add up to three marker areas (when enabled).
Picture-in-picture (PIP)—The fused, or blended, infrared/visible light
S
image appears in the center quarter of the display screen and the visible
light image appears in the rest of the display screen (when enabled).
IR Fusion blend level control box—Used to change the IR Fusion
T
blend level from full infrared (IR) to full visible light (VL) or some
combination in between (Only Ti45, Ti50, Ti55 IR Fusion models).