Configuration Tool
Requirements
PC
• Screen resolution of at least 1280x1024 pixels
• Java Runtime, at least V1.4.0 or higher
• Web browser, e.g. Microsoft Internet Explorer
• Connection via one of the four Ethernet ports of the device
SICLOCK TC 400
• Assignment of an IP address on the device
A valid IP address must be assigned for the Ethernet port of the device that is
to be used for the configuration.
Default addresses as delivered each with subnet mask 255.255.255.0:
− Port 1: 192.168.1.10
− Port 2: 192.168.2.20
− Port 3: 192.168.3.30
− Port 4: 192.168.4.40
PC must be in the same subnet.
Parameters, entries and lists
A parameter is considered as a group of associated values. Each value is desig-
nated as an entry of its parameter.
Parameters of the same kind can form a list. Such lists are displayed as [ ].
Notice
Entries can be edited individually, but not read or written individually. The param-
eter is always read or written with all its entries. If a list is being considered, the
entire list is read or written.
Parameters are identified by their unique parameter number. The parameter
number is always in three parts, e.g. 0.05.12.
7-46
© Siemens AG 2007 All Rights Reserved
SICLOCK
®
TC 400